Datasheet
G5NB-E
G5NB-E
UL508 (File No. 41515)
Coil ratings Contact ratings
5 to 24 VDC 5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
CSA C22.2 (No. 0, No. 1, No. 14) (File No. LR31928)
Coil ratings Contact ratings
5 to 24 VDC 5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
1. 120-VAC motor and lamp load (2.5-A surge and 0.5-A normal): 250,000 operations min.(at 23°C)
2. 160-VDC valve load (with varistor) (0.24-A): 250,000 operations min.(at 23°C)
Approved Standards
Actual Load Life (Reference Values)
Engineering Data
Contact voltage (V)
10
11030100 250 1,000
DC resistive
load
AC resistive
load
Contact
resistance
Maximum Switching Capacity
Contact current (A)
100
50
30
10
5
3
1
01234
250 VAC, 30 VDC resistive load
Endurance
Contact current (A)
No. of operations (x 10
4
)
5
3
1
0.1
Ambient Temperature vs. Maximum Coil Voltage
Maximum coil voltage (%)
Ambient temperature (°C)
Test item: G5NB-1A-E, 24 VDC
Quantity tested: 5
No current
3-A current
Z
Z
Z'
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
X
X
X'
X'
1,000
1,000
1,000
1,000
1,000 1,000
Excited
Not excited
700
125
Malfunctioning Shock
G5NB-1A
Quantity Tested: 5 units
Test Method: Shock was applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction was measured.
Rating: 100 m/s
2
Uncon-
firmed
area