Datasheet

G5NB-E
G5NB-E
Contact Rating
Coil Rating
Characteristics
Rated voltage 5 VDC 12 VDC 18 VDC 24 VDC
Rated current 40.0 mA 16.7 mA 11.1 mA 8.3 mA
Coil resistance 125 720 1,620 2,880
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 170% of rated voltage (at 23°C)
Power consumption Approx. 200 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
The operating characteristics are measured at a coil temperature of 23°C.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Load Resistive load (cosφ = 1)
Rated load 5 A at 250 VAC, 3 A at 30 VDC
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching power 1250 VA, 90 W
Failure rate (reference value) 10 mA at 5 VDC
Note: P level: λ
60
= 0.1 x 10
-6
/operation (with an operating frequency of 120 operations/min)
Contact resistance (See note 2.) 100 m max.
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance (See note 3.) 1,000 M min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 10,000 V (1.2 x 50 ms) between coil and contacts
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Endurance Mechanical: 5,000,000 operations min.
Electrical: 100,000 operations min (5 A at 250 VAC), 100,000 operations min. (3 A at 30 VDC)
Failure rate P level (reference value) 5 VDC, 10 mA
(See note 4.)
Ambient temperature Operating: -40˚C to 85˚C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 4 g
Note: 1. The data shown above are initial value.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method.
3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
4. This value is for a switching frequency of 120 operations/minute.