G3VM-601G@ MOS FET Relays
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item Symbol G3VM-601G1 G3VM-601G Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.1 1.0
V I
F=10 mATypical 1.27 1.15
Maximum 1.4 1.3
Reverse current IR Maximum 10 μAVR=5 V
Capacitance between
terminals
C
T Typical 30 pF V=0, f=1 MHz
Trigger LED forward
current
I
FT
Typical 0.4
mA
G3VM-601G1 : I
O
=70 mA
G3VM-601G : I
O
=90 mA
Maximum 0.2 1
Release LED forward
current
I
FC
Minimum 0.1
mA I
OFF=100 μA
Typical 0.001
Output
Maximum resistance with
output ON
R
ON
Typical 35 45
Ω
G3VM-601G1 : I
F
=0.5 mA, I
O
=70 mA, t < 1 s
G3VM-601G : I
F
=2 mA, I
O
=90 mA
Maximum 60
Current leakage when the
relay is open
I
LEAK
Typical 1
nA V
OFF
=600 V
Maximum 1,000
Capacitance between
terminals
C
OFF Typical 75 pF V=0, f=1 MHz
Capacitance between I/O
terminals
C
I-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance
between I/O terminals
R
I-O
Minimum 1000
MΩ V
I-O=500 VDC, ROH60%
Typical 10
8
Turn-ON time tON
Typical 2
ms
G3VM-601G1 : I
F
=0.5 mA, R
L
=200 Ω,
V
DD
=10 V *
G3VM-601G : I
F
=2 mA,
R
L
=200 Ω, V
DD
=10 V *
Maximum 10 8
Turn-OFF time tOFF
Typical 1 0.5
Maximum 5 3
* Turn-ON and Turn-OFF Times
Item Symbol G3VM-601G1 G3VM-601G Unit
Load voltage
(AC peak/DC)
V
DD Maximum 480 V
Operating LED forward
current
I
F
Typical 0.5 2
mA
Maximum 25
Continuous load current
(AC peak/DC)
IO Maximum 60 70
Ambient operating
temperature
Ta
Minimum -20
°C
Maximum 65
Item Minimum Unit
Creepage distances 4.0
mm
Clearance distances 4.0
Internal isolation thickness 0.1
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
4
3
R
L
V
DD
V
OUT