Datasheet
Product Table
49
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose High-load-voltage
Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Introduction
For PCBs Application
G3VM-41UR10 G3VM-41UR11 G3VM-51UR G3VM-61UR1 Model
1a (SPST-NO)
Contact form
VSON4 VSON4 VSON4 VSON4
Package
(Unit : mm, Average)
• Low-output-capacitance
and Low-ON-resistance
Type (with Low C
✕ R)
• Load voltage: 40 V
•Low C
✕ R = 5.4 pF · Ω
•C
OFF (typical) = 0.45 pF
• Low-output-capacitance
and Low-ON-resistance
Type (with Low C
✕ R)
• Load voltage: 40 V
• Low C
✕ R = 4.9 pF · Ω
•C
OFF (typical) = 0.7 pF
• Low-output-capacitance
and Low-ON-resistance
Type (with Low C
✕ R)
• Load voltage: 50 V
•Low C
✕ R = 12 pF · Ω
•R
ON (typical) =1 Ω
• Low-output-capacitance
and Low-ON-resistance
Type (with Low C
✕ R)
• Load voltage: 60 V
•Low C
✕ R = 7 pF · Ω
•C
OFF (typical) = 0.7 pF
Features
Photodiode coupler
Isolation method
40 V 50 V 60 V
AC peak
Load
voltage
Output
Absolute maximum ratings
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
30 mA
LED forward current
Input
300 VAC 50/60 Hz for 1 min.
Dielectric strength between I/O
-40 to +85°C
(with no icing or condensation)
Ambient operating
temperature
14 Ω 10 Ω 1.5 Ω 15 Ω
Maximum output ON
resistance
Output
Electrical
characteristics
1 nA (at 40 VDC) 1 nA (at 50 VDC) 1 nA (at 60 VDC)
Maximum OFF leakage
current
● (VSON)
Surface-mounting terminals
Terminal
structure
PCB terminals
Surface mounting
Mounting method
UL certification is pending
Applicable standards
Compliant
RoHS compliance
Approx. 0.01 g
Weight
195 195 195 213
Page
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.
* Refer to pages 218 to 220 for detailed information on models certified for standards.
1.3
1.45
2.45
1.3
1.45
2.45
1.3
1.45
2.45
1.3
1.45
2.45
120 mA
140 mA
300 mA
120 mA