Datasheet

Product Table
48
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose
Introduction
High-load-voltage Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Application For PCBs
Model G3VM-21UR10 G3VM-21UR1 G3VM-21UR11 G3VM-41UR12
Contact form 1a (SPST-NO)
Package
(Unit : mm, Average)
VSON4 VSON4 VSON4 VSON4
Features
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 20 V
•Low C
R = 2.4 pF · Ω
•C
OFF (typical) = 0.8 pF
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 20 V
Low C
R = 4 pF · Ω
•R
ON (typical) = 0.8 Ω
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 20 V
•Low C
R = 7.2 pF · Ω
•R
ON (typical) = 0.18 Ω
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
•Low C
R = 4.5 pF · Ω
•C
OFF (typical) = 0.3 pF
Isolation method Photodiode coupler
Absolute maximum ratings
Output
Load
voltage
AC peak
20 V 40 V
DC
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Input
LED forward current 30 mA
Dielectric strength between I/O
300 VAC 50/60 Hz for 1 min.
Ambient operating
temperature
-40 to +85°C
(with no icing or condensation)
Electrical
characteristics
Output
Maximum output ON
resistance
5 Ω 1.2 Ω 0.22 Ω 20 Ω
Maximum OFF leakage
current
1 nA (at 20 VDC) 1 nA (at 40 VDC)
Terminal
structure
Surface-mounting terminals (VSON)
PCB terminals
Mounting method Surface mounting
Applicable standards UL certification is pending
RoHS compliance Compliant
Weight Approx. 0.01 g
Page 190 190 190 195
1.3
1.45
2.45
1.3
1.45
2.45
1.3
1.45
2.45
1.3
1.45
2.45
200 mA
450 mA
1,000 mA
100 mA
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.
* Refer to pages 218 to 220 for detailed information on models certified for standards.