Datasheet

Product Table
42
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose
Introduction
High-load-voltage Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Application For PCBs
Model G3VM-41LR10 G3VM-41LR6 G3VM-41LR11 G3VM-41LR4
Contact form 1a (SPST-NO)
Package
(Unit : mm, Average)
SSOP4 SSOP4 SSOP4 SSOP4
Features
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
•Low C
R = 5.4 pF · Ω
•C
OFF (typical) = 0.45 pF
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
Low C
R = 10 pF · Ω
•C
OFF (typical) = 1 pF
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
•Low C
R = 4.9 pF · Ω
•C
OFF (typical) = 0.7 pF
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
•Low C
R = 10 pF · Ω
•R
ON (typical) = 2 Ω
Isolation method Photodiode coupler
Absolute maximum ratings
Output
Load
voltage
AC peak
40 V
DC
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Input
LED forward current 30 mA 50 mA 30 mA 50 mA
Dielectric strength between I/O
1,500 VAC 50/60 Hz for 1 min.
Ambient operating
temperature
-20 to +85°C
(with no icing or condensation)
Electrical
characteristics
Output
Maximum output ON
resistance
14 Ω 15 Ω 10 Ω 3 Ω
Maximum OFF leakage
current
0.2 nA (at 35 VDC) 1 nA (at 30 VDC) 0.2 nA (at 35 VDC) 1 nA (at 30 VDC)
Terminal
structure
Surface-mounting terminals (SSOP)
PCB terminals
Mounting method Surface mounting
Applicable standards UL
RoHS compliance Compliant
Weight Approx. 0.03 g
Page 175 175 175 175
3.8
2.04
1.8
3.8
2.04
1.8
3.8
2.04
1.8
3.8
2.04
1.8
120 mA
120 mA
140 mA
250 mA
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.
* Refer to pages 218 to 220 for detailed information on models certified for standards.