Datasheet

Product Table
31
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose High-load-voltage
Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Introduction
For PCBs Application
G3VM-61VY1 G3VM-61G1 G3VM-61G2 G3VM-61G3 G3VM-61VY2 Model
1a (SPST-NO)
Contact form
Special SOP4 SOP4 SOP4 SOP4 Special SOP4
Package
(Unit : mm, Average)
General-purpose
Type
Load voltage: 60 V
Dielectric strength
between I/O:
3,750 VAC
General-purpose
Type
Load voltage: 60 V
General-purpose
Type
Load voltage: 60 V
Trigger LED
forward current
: 1 mA max.
General-purpose
Type
Load voltage: 60 V
Trigger LED
forward current
: 0.2 mA max.
General-purpose Type
Continuous load current :
0.5A max.
Dielectric strength
between I/O: 3,750 VAC
High Ambient operating
temperature: -40 to +110
°C
Features
Photodiode coupler
Isolation method
60 V
AC peak
Load
voltage
Output
Absolute maximum ratings
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
30 mA 50 mA 30 mA
LED forward current
Input
3,750 VAC 50/60 Hz for 1 min.
1,500 VAC 50/60 Hz for 1 min.
3,750 VAC 50/60 Hz for 1 min.
Dielectric strength between I/O
-40 to +85°C
(with no icing or condensation)
-40 to +110°C
(with no icing or condensation)
Ambient operating
temperature
50 Ω 2 Ω
Maximum output ON
resistance
Output
Electrical
characteristics
1 μA (at 60 VDC)
Maximum OFF leakage
current
(SOP)
Surface-mounting terminals
Terminal
structure
PCB terminals
Surface mounting
Mounting method
UL
Applicable standards
Compliant
RoHS compliance
Approx. 0.1 g
Weight
68 68 68 68 68
Page
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.
* Refer to pages 218 to 220 for detailed information on models certified for standards.
2.1
4.55
3.7
2.1
4.4
3.9
2.1
4.4
3.9
2.1
4.4
3.9
2.1
4.55
3.7
100 mA
400 mA
400 mA
400 mA
500 mA