Datasheet
Product Table
20
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose
Introduction
High-load-voltage Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Application For PCBs
Model
G3VM-61AY1
G3VM-61DY1
G3VM-61AR
G3VM-61DR
G3VM-61B1
G3VM-61E1
G3VM-61BR
G3VM-61ER
Contact form 1a (SPST-NO)
Package
(Unit : mm, Average)
DIP4 DIP4 DIP6 Special DIP6
Features
• Small and High-dielectric-
strength Type
• Load voltage: 60 V
• Dielectric strength between
I/O: 5,000 VAC
• High-current and Low-ON-
resistance Type
• Load voltage: 60 V
• Continuous load current
: 2 A max.
• General-purpose Type
• Load voltage: 60 V
• High-current and Low-ON-
resistance Type
• Load voltage: 60 V
• Continuous load current:
2.5 A max.
Isolation method Photodiode coupler
Absolute maximum ratings
Output
Load
voltage
AC peak
60 V
DC
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Input
LED forward current 30 mA 50 mA 30 mA
Dielectric strength between I/O
5,000 VAC 50/60 Hz for 1 min.
2,500 VAC 50/60 Hz for 1 min.
Ambient operating
temperature
-40 to +85°C
(with no icing or condensation)
Electrical
characteristics
Output
Maximum output ON
resistance
2 Ω 0.2 Ω
Connection A: 2 Ω
Connection B: 1 Ω
Connection C: 0.25 Ω (typical)
0.1 Ω
Maximum OFF leakage
current
1 μA (at 60 VDC) 10 nA (at 60 VDC)
Terminal
structure
Surface-mounting terminals ●
PCB terminals ●
Mounting method
PCB mounting or
Surface mounting
Applicable standards UL
RoHS compliance Compliant
Weight Approx. 0.25 g Approx. 0.4 g
Page 147 110 62 115
3.65
6.4
4.58
3.65
6.4
4.58
3.65
6.4
4.58
3.65
6.4
4.58
7.12
3.65
6.4
7.12
3.65
6.4
7.12
3.65
6.4
7.12
3.65
6.4
500 mA
2,000 mA
* Connection C
1,000 mA
500 mA
2,500 mA
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.
* Refer to pages 218 to 220 for detailed information on models certified for standards.