Datasheet

191
G3VM-21UR@ MOS FET Relays
DIP
SOP
SSOP
USOP
VSON
S-VSON
Introduction
General-purpose
Small and High-
load-voltage
Certified Models with
Standards Certification
G3VM-21UR
@
High-dielectric-
strengthHigh-load-voltage
Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Absolute Maximum Ratings (Ta = 25°C)
* The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the
light-receiving side.
Electrvical Characteristics (Ta = 25°C)
* Turn-ON and Turn-OFF Times
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Item Symbol G3VM-21UR10 G3VM-21UR1 G3VM-21UR11 Unit Measurement conditions
Input
LED forward current IF 30 mA
LED forward current reduction rate ΔIF/°C 0.3 mA/°C Ta25°C
LED reverse voltage VR 5 V
Connection temperature TJ 125 °C
Output
Load voltage (AC peak/DC) VOFF 20 V
Continuous load current (AC peak/DC) IO 200 450 1,000 mA
ON current reduction rate ΔIO/°C 2 4.5 10 mA/°C Ta25°C
Pulse ON current lop 0.6 1.3 3 A t=100 ms, Duty=1/10
Connection temperature TJ 125 °C
Dielectric strength between I/O * VI-O 300 Vrms AC for 1 min
Ambient operating temperature Ta 40 to +85 °C
With no icing or condensation
Ambient storage temperature Tstg 40 to +125 °C
Soldering temperature 260 °C 10 s
Item Symbol G3VM-21UR10 G3VM-21UR1 G3VM-21UR11 Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.1
V I
F=10 mATypical 1.27
Maximum 1.4
Reverse current IR Maximum 10 μAVR=5 V
Capacitance between terminals CT Typical 30 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 1 0.6
mA I
O=100 mA
Maximum 3
Release LED forward current IFC Minimum 0.1 mA IOFF=10 μA
Output
Maximum resistance with output
ON
R
ON
Typical 3 0.8 0.18
Ω
I
F=5 mA, t<1 s,
I
O=Continuous load current ratings
Maximum 5 1.2 0.22
Current leakage when the relay
is open
I
LEAK Maximum 1 nA VOFF=20 V
Capacitance between terminals COFF
Typical 0.8 5 40
pF V=0, f=100 MHz, t<1 s
Maximum 1.1 12
Capacitance between I/O terminals CI-O Typical 1 0.4 pF f=1 MHz, VS=0 V
Insulation resistance between I/O
terminals
R
I-O Typical 10
8
MΩ VI-O=500 VDC, ROH60%
Turn-ON time tON
Typical 0.05 0.17
ms
I
F=5 mA, RL=200 Ω,
V
DD=10 V *
Maximum 0.2 0.4 2
Turn-OFF time tOFF
Typical 0.02
Maximum 0.2 0.4 1
Item Symbol G3VM-21UR10 G3VM-21UR1 G3VM-21UR11 Unit
Load voltage (AC peak/DC) VDD Maximum 16 V
Operating LED forward current IF
Minimum 5
mA
Typical 7.5
Maximum 20
Continuous load current (AC peak/DC) IO Maximum 200 450 1,000
Ambient operating temperature Ta
Minimum 20
°C
Maximum 65
V
OUT
I
F
tON tOFF
10%
90%
IF
1
2
4
3
RL
VDD
VOUT