G3VM-@L/@FL/@GL MOS FET Relays
■Electrical Characteristics (Ta = 25°C)
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
■Spacing and Insulation
Item Symbol
G3VM-2L
G3VM-2FL
G3VM-WL
G3VM-WFL
G3VM-351GL Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.0
V I
F=10 mATypical 1.15
Maximum 1.3
Reverse current IR Maximum 10 μA
G3VM-2L/2FL/WL/WFL : V
R=6 V
G3VM-351GL : V
R=5 V
Capacitance between terminals CT Typical 30 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 1
mA
I
O
=120 mA
Maximum 3
Release LED forward current IFC Minimum 0.1 mA
G3VM-2L/2FL/WL/WFL : I
OFF=10 μA
G3VM-351GL : I
OFF=100 μA
Output
Maximum resistance with output
ON
R
ON
Typical 22 15
Ω I
F=5 mA,
I
O
=120 mA
Maximum 35
Current leakage when the relay is
open
I
LEAK Maximum 1.0 μA VOFF=350 V
Capacitance between terminals COFF Typical 40 70 pF V=0, f=1 MHz
Limit current ILIM
Minimum 150
mA
I
F
=5 mA,
VDD=5 V, t=5 ms
Maximum 300
Capacitance between I/O terminals CI-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance between I/O
terminals
R
I-O
Minimum 1000
MΩ V
I-O=500 VDC, ROH≤60%
Typical 10
8
Turn-ON time tON
Typical − 0.3
ms
I
F
=5 mA, R
L
=200
Ω
,
VDD=2 V *
Maximum 1.0
Turn-OFF time tOFF
Typical − 0.1
Maximum 1.0
* Turn-ON and Turn-OFF Times
Item Symbol
G3VM-2L
G3VM-2FL
G3VM-WL
G3VM-WFL
G3VM-351GL Unit
Load voltage (AC peak/DC) VDD Maximum 280 V
Operating LED forward current IF
Minimum 5
mA Typical 7.5
Maximum 25
Continuous load current (AC peak/DC) IO Maximum 100 A
Ambient operating temperature Ta
Minimum -20
°C
Maximum 65
Item
Minimum
Unit
G3VM-@L/@FL G3VM-@GL
Creepage distances 7.0 2.5
mm
Clearance distances 7.0 2.5
Internal isolation thickness 0.4 0.1
VOUT
IF
tON tOFF
10%
90%
IF
1
2
4
3
RL
VDD
VOUT
IF
1(3)
2(4)
8(6)
7(5)
RL
VDD