G3VM-@CR@/@FR@ MOS FET Relays
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item
Symbol
G3VM-61CR1
G3VM-61FR1
G3VM-101CR
G3VM-101FR
G3VM-201CR
G3VM-201FR
G3VM-401CR
G3VM-401FR
G3VM-601CR
G3VM-601FR
Unit Measurement conditions
Input
LED forward voltage VF
Minimum
1.5
V I
F=10 mA
Typical
1.64
Maximum
1.8
Reverse current IR
Maximum
10 μAVR=5 V
Capacitance between
terminals
C
T
Typical
70 pF V=0, f=1MHz
Trigger LED forward
current
I
FT
Typical
0.28 0.3 0.3 0.2 0.23
mA
G3VM-61CR1/FR1 : I
O=1 A
G3VM-101CR/FR : I
O=1 A
G3VM-201CR/FR : I
O=1 A
G3VM-401CR/FR : I
O=0.4 A
G3VM-601CR/FR : I
O=0.6 A
Maximum
55515
Release LED forward
current
I
FC
Minimum
0.01
mA
G3VM-61CR1/FR1 : I
OFF=1 μA
G3VM-101CR/FR : I
OFF=1 μA
G3VM-201CR/FR : I
OFF=1 μA
G3VM-401CR/FR : I
OFF=10 μA
G3VM-601CR/FR : I
OFF=1 μA
Typical
0.19 - 0.19 0.17
Output
Maximum
resistance
with
output ON
Connection
A
R
ON
Typical
0.022 0.06 0.25 3 1.3
Ω
G3VM-61CR1/FR1 : I
O
=1 A, I
F
=5 mA,
t< 1 s
G3VM-101CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : I
O
=0.4 A, I
F
=2 mA,
t < 1 s
G3VM-601CR/FR : I
O
=0.6 A, I
F
=5 mA,
t < 1 s
Maximum
0.05 0.15 0.5 5 2
Connection
B
Maximum
0.025 0.075 0.25 2.5 1
G3VM-61CR1/FR1 : I
O
=1 A, I
F
=2 mA,
t < 1 s
G3VM-101CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : IO=0.4 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=0.6 A, IF=2 mA, t < 1 s
Connection
C
Maximum
0.013 0.075 0.25 1.3 0.5
G3VM-61CR1/FR1 : IO=1 A, IF=2 mA,
t < 1 s
G3VM-101CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : I
O=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : IO=0.8 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=1.2 A, IF=2 mA, t < 1 s
Current leakage when
the relay is open
I
LEAK
Typical
0.01 0.02 0.1 0.001 0.05
μA V
OFF=Load Voltage Ratings
Maximum
10 1 1 1 10
Capacitance between
terminals
C
OFF
Typical
850 720 400 410 4,300 pF V=0, f=1 MHz
Capacitance between I/O
terminals
C
I-O
Typical
0.8 pF f=1 MHz, VS=0 V
Insulation resistance
between I/O terminals
R
I-O
Minimum
1,000
MΩ V
I-O=500 VDC, ROH60%
Typical
10
8
Turn-ON time tON
Typical
2.5 1.5 0.25 0.22 0.8
ms I
F =5 mA, RL =200 Ω, VDD=20 V *
Maximum
513
Turn-OFF time tOFF
Typical
0.1 0.08 0.07
Maximum
1
* Turn-ON and Turn-OFF Times
Item Symbol
G3VM-61CR1
G3VM-61FR1
G3VM-101CR
G3VM-101FR
G3VM-201CR
G3VM-201FR
G3VM-401CR
G3VM-401FR
G3VM-601CR
G3VM-601FR
Unit
Load voltage (AC peak/DC) VDD Maximum 48 80 160 320 480 V
Operating LED forward current IF
Typical55525
mA
Maximum 25
Continuous load current (AC peak/DC)
IO Maximum 5 3 1.5 0.4 0.6 A
Ambient operating temperature Ta
Minimum -40
°C
Maximum 85
Item Minimum Unit
Creepage distances 7.0
mm
Clearance distances 7.0
Internal isolation thickness 0.4
VOUT
IF
tON tOFF
10%
90%
IF
2
3
5
8
RL
VDD
VOUT