Datasheet
112
G3VM-@AR/@DR MOS FET Relays
DIP
SOP
SSOP
USOP
VSON
S-VSON
Introduction
General-purpose Small and High-
dielectric-strength
High-dielectric-
strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
G3VM-
@
AR/
@
DR
High-load-voltage Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
■Electrical Characteristics (Ta = 25°C)
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
■Spacing and Insulation
Item Symbol
G3VM-21AR
G3VM-21DR
G3VM-41AR
G3VM-41DR
G3VM-61AR
G3VM-61DR
G3VM-101AR
G3VM-101DR
Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.18
V I
F=10 mATypical 1.33
Maximum 1.48
Reverse current IR Maximum 10 μAVR=5 V
Capacitance
between terminals
C
T Typical 70 pF V=0, f=1 MHz
Trigger LED forward
current
IFT
(IFC)
Typical 0.7 0.5
mA
I
O
=1 A
Maximum 3
Release LED
forward current
IFC
(IFT)
Minimum 0.1 mA I
OFF=10 μA
Output
Maximum resistance
with output ON
R
ON
Typical 40 50 80 250
mΩ
G3VM-21AR/21DR/41AR/41DR/61AR/61DR :
IF=5 mA, t < 1s, IO=2 A
G3VM-101AR/DR :
I
F=5 mA, t < 1s, IO=1 A
Maximum 80 150 200 700
Current leakage
when the relay is
open
I
LEAK Maximum 1 μA VOFF=Load voltage ratings
Capacitance
between terminals
C
OFF Typical 300 250 200 pF V=0, f=1 MHz
Capacitance between I/
O terminals
C
I-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance
between I/O terminals
R
I-O
Minimum 1000
MΩ V
I-O=500 VDC, ROH≤60%
Typical 10
8
Turn-ON time tON
Typical 1 0.8
ms
I
F
=5 mA, R
L
=200
Ω
,
VDD=20 V *
Maximum 5
Turn-OFF time tOFF
Typical 0.3
Maximum 1
* Turn-ON and Turn-OFF Times
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
4
3
R
L
V
DD
V
OUT
Item Symbol
G3VM-21AR
G3VM-21DR
G3VM-41AR
G3VM-41DR
G3VM-61AR
G3VM-61DR
G3VM-101AR
G3VM-101DR
Unit
Load voltage (AC peak/DC) VDD Maximum 16 32 48 80 V
Operating LED forward current IF
Minimum 5
mA Typical 10
Maximum 25
Continuous load current (AC peak/DC)
IO Maximum 3 2.5 2 1 A
Ambient operating temperature Ta
Minimum -20
°C
Maximum 65
Item Minimum Unit
Creepage distances 7.0
mm
Clearance distances 7.0
Internal isolation thickness 0.4