30
DIP
SOP
SSOP
USOP
VSON
S-VSON
General-purpose
Introduction
High-load-voltage Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
High-dielectric-
strength
Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
Product Table
Application For PCBs
Model G3VM-41GR4 G3VM-41GR5 G3VM-41GR8 G3VM-41HR
Contact form 1a (SPST-NO)
Package
(Unit : mm, Average)
SOP4 SOP4 SOP4 SOP6
Features
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
•Low C
R = 10 pF · Ω
•R
ON (typical) = 2 Ω
Low-output-capacitance
and Low-ON-resistance
Type (with Low C
R)
Load voltage: 40 V
Low C
R = 10 pF · Ω
•R
ON (typical) = 1 Ω
High-current and Low-ON-
resistance Type
Load voltage: 40 V
Continuous load current:
1 A max.
High-current and Low-ON-
resistance Type
Load voltage: 40 V
Continuous load current
: 2.5 A (5 A) max. *
* Values in parentheses are
for connection C.
Isolation method Photodiode coupler
Absolute maximum ratings
Output
Load
voltage
AC peak
40 V
DC
Continuous
load current
AC peak/ DC
* 6-pin type
connection C:
DC
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
2,000
1,000
900
800
700
600
500
400
300
200
100
Input
LED forward current 50 mA 30 mA
Dielectric strength between I/O
1,500 VAC 50/60 Hz for 1 min.
Ambient operating
temperature
-20 to +85°C
(with no icing or condensation)
-40 to +85°C
(with no icing or condensation)
Electrical
characteristics
Output
Maximum output ON
resistance
3 Ω 1.5 Ω 0.13 Ω
Connection A: 0.06 Ω
Connection B: 0.03 Ω
Connection C: 0.008
Ω
(typical)
Maximum OFF leakage
current
1 nA (at 30 VDC) 10 nA (at 40 VDC)
Terminal
structure
Surface-mounting terminals (SOP)
PCB terminals
Mounting method Surface mounting
Applicable standards UL
RoHS compliance Compliant
Weight Approx. 0.1 g Approx. 0.13 g
Page 165 165 127 131
2.1
4.4
3.9
2.1
4.4
3.9
2.1
4.4
3.9
2.1
4.4
6.3
250 mA
300 mA
1,000 mA
* Connection C
5,000 mA
2,500 mA
* Only basic specifications are given in this table. Refer to the reference page given in the table for detailed specifications and precautions before you attempt to use a Relay.