205
G3VM-61LR/81LR/101LR MOS FET Relays
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item Symbol G3VM-61LR G3VM-81LR G3VM-101LR Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.0
V I
F=10 mA Typical 1.15
Maximum 1.3
Reverse current IR Maximum 10 μAV
R
=5 V
Capacitance between
terminals
C
T Typical 15 pF V=0, f=1 MHz
Trigger LED forward
current
I
FT
Typical 2 1
mA
G3VM-61LR : I
O
=100 mA
G3VM-81LR : I
O
=120 mA
G3VM-101LR : I
O
=80 mA
Maximum 5
Release LED forward
current
I
FC Minimum 0.2 0.1 0.2 mA
G3VM-61LR/81LR : I
OFF=10 μA
G3VM-101LR : I
OFF=1 μA
Output
Maximum resistance with
output ON
R
ON
Typical 1 7.5 8
Ω
G3VM-61LR : I
F
=5 mA,
I
O=Continuous load current ratings
G3VM-81LR/101LR : I
F
=10 mA,
I
O=Continuous load current ratings,
t=10 ms
Maximum 1.5 12 14
Current leakage when the
relay is open
I
LEAK Maximum 1,000 0.2 nA
G3VM-61LR : V
OFF=60 V
G3VM-81LR : V
OFF=80 V, Ta=60°C
G3VM-101LR : V
OFF=80 V
Capacitance between
terminals
C
OFF
Typical 20 5 6
pF V=0, f=100 MHz, t<1 s
Maximum 30 7 8
Capacitance between I/O
terminals
C
I-O Typical 0.3 0.8 0.6 pF f=1 MHz, V
S
=0 V
Insulation resistance between
I/O terminals
R
I-O
Minimum 1000
MΩ V
I-O
=500 VDC, R
O
H60%
Typical 10
8
Turn-ON time tON
Typical 0.3 0.1
ms
G3VM-81LR :
I
F
=10 mA, R
L
=200 Ω, V
DD
=20 V
G3VM-61LR/101LR :
I
F
=5 mA, R
L
=200 Ω, V
DD
=20 V *
Maximum 1 0.25 0.3
Turn-OFF time tOFF
Typical 0.2 0.15 0.1
Maximum 1 0.2 0.3
* Turn-ON and Turn-OFF Times
Item Symbol G3VM-61LR G3VM-81LR G3VM-101LR Unit
Load voltage (AC peak/DC) VDD Maximum486480V
Operating LED forward current IF
Minimum 10
mA Maximum 20 30
Continuous load current (AC peak/DC) IO Maximum 400 120 80
Ambient operating temperature Ta
Minimum -20
°C
Maximum 70 60
Item Minimum Unit
Creepage distances 2.5
mm
Clearance distances 2.5
Internal isolation thickness 0.1
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
4
3
R
L
V
DD
V
OUT