Datasheet
149
G3VM-@AY@/@DY@ MOS FET Relays
DIP
SOP
SSOP
USOP
VSON
S-VSON
Introduction
General-purpose
High-dielectric-
strength Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
G3VM-
@
AY
@
/
@
DY
@
High-load-voltage
Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
Small and High-
dielectric-strength
■Electrical Characteristics (Ta = 25°C)
Standard type
High sensitive type
Item Symbol
G3VM-41AY1
G3VM-41DY1
G3VM-61AY1
G3VM-61DY1
G3VM-201AY1
G3VM-201DY1
G3VM-351AY1
G3VM-351DY1
G3VM-401AY1
G3VM-401DY1
G3VM-601AY1
G3VM-601DY1
Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.1
VI
F=10 mATypical 1.27
Maximum 1.4
Reverse current IR Maximum 10 μAVR=5 V
Capacitance between terminals CT Typical 50 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 0.5 0.6 0.5
mA
G3VM-41AY1/DY1 : I
O
=1 A
Others : I
O
=Continuous load
current ratings
Maximum 3
Release LED forward current IFC Minimum 0.1 mA I
OFF
=10 μA
Output
Maximum resistance with output ON RON
Typical
0.09
(0.06)
0.6 5
35
(25)
22
(17)
45
(30)
Ω
I
F
=5 mA,
I
O
=Continuous load current
ratings
Values in parentheses are for t < 1 s.
Maximum
0.15
(0.10)
28
50
(35)
35
(28)
60
(40)
Current leakage when the relay is
open
I
LEAK Maximum 1 μA
V
OFF
=Load voltage ratings
Capacitance between terminals COFF Typical 300 130 90 30 80 75 pF V=0, f=1 MHz
Capacitance between I/O terminals CI-O Typical 0.8 pF f=1 MHz, V
S
=0 V
Insulation resistance between I/O
terminals
R
I-O
Minimum 1000
MΩ V
I-O
=500 VDC, R
O
H≤60%
Typical 10
8
Turn-ON time tON
Typical 2.8 1 0.3 0.6 0.5
ms
G3VM-41AY1/DY1 :
R
L
=200
Ω
, I
F
=10 mA, V
DD
=20 V
G3VM-601AY1/DY1 : R
L
=200
Ω
,
I
F
=5 mA, V
DD
=10 V
Others :
R
L
=200
Ω
, I
F
=5 mA, V
DD
=20 V
*
Maximum 5 3 2
Turn-OFF time tOFF
Typical 0.3 0.2 0.1 0.2
Maximum 1
* Turn-ON and Turn-OFF Times
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
4
3
R
L
V
DD
V
OUT
Item Symbol
G3VM-41AY
G3VM-41DY
G3VM-61AY
G3VM-61DY
G3VM-201AY
G3VM-201DY
G3VM-351AY
G3VM-351DY
G3VM-401AY
G3VM-401DY
G3VM-601AY
G3VM-601DY
Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.45
VI
F=10 mATypical 1.63
Maximum 1.75
Reverse current IR Maximum 10 μAVR=5 V
Capacitance between terminals CT Typical 40 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 0.3
mA
G3VM-41AY/DY : I
O
=1 A
Others : I
O
=Continuous load
current ratings
Maximum 2
Release LED forward current IFC Minimum 0.1 mA IOFF=10 μA
Output
Maximum resistance with output ON RON
Typical
0.09
(0.06)
0.6 5
35
(25)
22
(17)
45
(30)
Ω
I
F
=5 mA,
I
O
=Continuous load current
ratings
Values in parentheses are for t < 1 s.
Maximum
0.15
(0.10)
28
50
(35)
35
(28)
60
(40)
Current leakage when the relay is
open
I
LEAK Maximum 1 μA
V
OFF
=Load voltage ratings
Capacitance between terminals COFF Typical 300 130 90 30 80 75 pF V=0, f=1 MHz
Capacitance between I/O terminals CI-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance between I/O
terminals
R
I-O
Minimum 1000
MΩ V
I-O=500 VDC, ROH≤60%
Typical 10
8
Turn-ON time tON
Typical 2 0.5 0.1 0.2
ms
G3VM-601AY/DY :
R
L
=200
Ω
, I
F
=5 mA, V
DD
=10 V
Others :
R
L
=200
Ω
, I
F
=5 mA, V
DD
=20 V
*
Maximum 5 1
Turn-OFF time tOFF
Typical 0.3 0.2
Maximum 1
* Turn-ON and Turn-OFF Times
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
4
3
R
L
V
DD
V
OUT