Datasheet

DIP
SOP
SSOP
USOP
VSON
S-VSON
Introduction
General-purpose
Small and High-
dielectric-strength
High-dielectric-
strength Current-limiting
Low-output-capacitance
and Low-ON-resistance
Small and High-
load-voltage
Certified Models with
Standards Certification
G3VM-21HR/31HR/41HR/61HR/61HR1
High-load-voltage
Multi-contact-pair
(2a, 2b, and 1a1b)
High-current and
Low-ON-resistance
133
G3VM-21HR/31HR/41HR/61HR/61HR1 MOS FET Relays
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item Symbol G3VM-21HR G3VM-31HR G3VM-41HR G3VM-61HR
G3VM-61HR1
Unit Measurement conditions
Input
LED forward voltage VF
Minimum 1.18
V I
F=10 mATypical 1.33
Maximum 1.48
Reverse current IR Maximum 10 μAVR=5 V
Capacitance between
terminals
C
T Typical 70 pF V=0, f=1 MHz
Trigger LED forward current IFT
Typical 0.3 0.4
0.2
mA
G3VM-61HR1 : I
O=2000 mA
Others :
IO=100 mA
Maximum 3
Release LED forward current IFC Minimum 0.1 mA IOFF=10 μA
Output
Maximum
resistance
with output
ON
Connection A
R
ON
Typical
0.02 0.02 0.03 0.04 0.03
Ω
G3VM-31HR:
I
F=5 mA
I
O=4 A (Connection A, B)
I
O=8 A (C connections), t<1s
Others:
I
F=5 mA
I
O=2 A (Connection A, B)
I
O=4 A (C connections), t<1s
Connection B 0.01 0.008 0.015 0.02 0.015
Connection C 0.005 0.004 0.008 0.01 0.008
Connection A
Maximum
0.05 0.04 0.06 0.07 0.06
Connection B 0.025 0.02 0.03 0.04
Connection C 0.01
Current leakage when the
relay is open
I
LEAK
Typical
nA V
OFF= Load voltage ratings
Maximum 10 1000 10
20
Capacitance between
terminals
C
OFF
Typical 1000 1100 1000
700
pF V=0, f=1 MHz
Maximum
1500
Capacitance between I/O
terminals
C
I-O Typical 0.8 pF f=1 MHz, VS=0 V
Insulation resistance between I/O
terminals
R
I-O
Minimum 1000
MΩ V
I-O=500 VDC, ROH60%
Typical 10
8
Turn-ON time tON
Typical 1.5 1.1 1.0
0.6
ms
G3VM-21HR :
I
F=5 mA, RL=200 Ω,
V
DD=10 V *
Others :
IF=5 mA, RL=200 Ω,
V
DD=20 V *
Maximum 5
Turn-OFF time tOFF
Typical 0.1 0.1 0.15
0.2
Maximum 1
* Turn-ON and Turn-OFF Times
Item Symbol G3VM-21HR G3VM-31HR G3VM-41HR G3VM-61HR G3VM-61HR1 Unit
Load voltage (AC peak/DC) VDD Maximum 20 24 40 60 48 V
Operating LED forward current IF
Minimum 5
mA
Typical 10 7.5 10
Maximum 20 25 20 25
Continuous load current (AC peak/DC)
IO Maximum 2000 4000
2000
1800 3300
Ambient operating temperature Ta
Minimum -20
°C
Maximum 65
Item Minimum Unit
Creepage distances 4.0
mm
Clearance distances 4.0
Internal isolation thickness 0.1
VOUT
IF
t
ON
t
OFF
10%
90%
I
F
1
2
6
4
R
L
V
DD
V
OUT