Datasheet
G2R
G2R
5
PCB/Fully sealed Relays
Item General-purpose (single contact) Bifurcated contact
Number of poles
1 pole 2 poles 1 pole
Load
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Rated load
8 A at 250
VAC;
8 A at 30 VDC
6 A at 250 VAC;
4 A at 30 VDC
4 A at 250
VAC;
4 A at 30 VDC
1.5 A at 250
VAC;
2.5 A at 30 VDC
5 A at 250
VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
Rated carry current
8A 4A 5A
Max. switching voltage
380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current
8A 4A 5A
Max. switching power
2,000 VA,
240 W
1,500 VA,
120 W
1,000 VA,
120 W
375 VA,
75 W
1,250 VA,
150 W
500 VA,
90 W
Min. permissible load
100 mA at 5 VDC 10 mA at 5 VDC 1mAat5VDC
Note:
P level:
%
60
=0.1x10
-6
/operation
Latching Relays
Number of poles
1 pole 2 poles
Load
Resistive load
(cos
$
=1)
Inductive load
(cos
$
= 0.4; L/R = 7
ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
= 0.4; L/R = 7
ms)
Rated load
5 A at 250 VAC;
5 A at 30 VDC
3.5 A at 250 VAC;
2.5 A at 30 VDC
3 A at 250 VAC;
3 A at 30 VDC
1.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current
5A 3A
Max. switching voltage
380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current
5A 3A
Max. switching power
1,250 VA, 150 W 875 VA, 75 W 750 VA, 90 W 375 VA, 60 W
Min. permissible load
100 mA at 5 VDC 10 mA at 5 VDC
Note:
P level:
%
60
=0.1x10
-- 6
/operation
Characteristics
Standard Relays
Item 1 pole 2 poles
Contact resistance
30 m
!
max. (high-capacity type: 100 m
!
max.) 50 m
!
max.
Operate (set) time
15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
!
min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: 200 m/s
2
when energized; 100m/s
2
when no energized
Life expectancy
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature
Operating: --40
"
Cto70
"
C (with no icing)
Storage: --40
"
Cto70
"
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Storage: 35% to 85%
Weight
Approx. 17 g (plug-in terminal: approx. 20 g)
Note:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.