Datasheet

G2R
G2R
4
Double-winding Latching Relays
Rated voltage
5VDC 6VDC 12 VDC 24 VDC
Set coil Rated current*
167 mA 138 mA 70.6 mA 34.6 mA
Coil resistance*
30
!
43.5
!
170
!
694
!
Coil inductance Armature OFF
0.073 0.104 0.42 1.74
(H) (ref. value) Armature ON
0.146 0.208 0.83 3.43
Reset coil Rated current
119 mA 100 mA 50 mA 25 mA
Coil resistance
42
!
60
!
240
!
960
!
Coil inductance Armature OFF
0.003 0.005 0.018 0.079
(H) (ref. value) Armature ON
0.006 0.009 0.036 0.148
Must set voltage
70% of rated voltage
Must reset voltage
70% of rated voltage
Max. voltage
110% of rated voltage
Power consum ption
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW
*Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
"
C with a tolerance of
#
10%.
2. Operating characteristics are measured at a coil temperature of 23
"
C.
Contact Ratings
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays
Item General-purpose, quick-connect
terminal, plug-in 1/2/3*
Quick-connect terminal,
plug-in 4*
High-capacity
Number of poles
1 pole 2 poles 1 pole
Load
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Rated load
10 (1) A at
250 VAC;
10 (1) A at
30 VDC
7.5 A at
250 VAC;
5 A at 30 VDC
5Aat
250 VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
16 A at
250 VAC;
16 A at
30 VDC
8 A at 250 VAC;
8 A at 30 VDC
Rated carry current
10 (1) A 5A 16 A
Max. switching voltage
380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current
10 (1) A 5A 16 A
Max. switching power
2,500 (250) VA,
300 (30) W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
4,000 VA,
480 W
2,000 VA,
240 W
Min. permissible load
100 mA at 5 VDC (1 mA at 5 VDC) 10 mA at 5 VDC 100 mA at 5 VDC
Note:
1. P level:
%
60
=0.1x10
-6
/operation
*2.Plug-in type 1: standard; 2: w/operation indicator; 3: w/diode; 4: w/operation indicator and diode
3. ( ): Bifurcated crossbar contact type.
PCB/Flux Protection Relays
Item Bifurcated contacts High-sensitivity
Number of poles
1 pole 1 pole 2 poles
Load
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Resistive load
(cos
$
=1)
Inductive load
(cos
$
=0.4;
L/R = 7 ms)
Rated load
5 A at 250
VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
5 A at 250
VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
3 A at 250
VAC;
3 A at 30 VDC
1 A at 250 VAC;
1.5 A at 30 VDC
Rated carry current
5A 5A 3A
Max. switching voltage
380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current
5A 5A 3A
Max. switching power
1,250 VA,
150 W
500 VA,
90 W
1,250 VA,
150 W
500 VA,
90 W
750 VA,
90 W
250 VA,
45 W
Min. permissible load
1mAat5VDC 100 mA at 5 VDC 10 mA at 5 VDC
Note:
P level:
%
60
=0.1x10
-6
/operation