Server User Manual
Klinkmann Automation Omron Ethernet DAServer  13 
Omron Ethernet DAServer Ver 1.x User Manual Rev 1.4    17014m14 
Enter Address Conversion type, FINS UDP port number and Sub-net Mask. 
Edit the IP Address Table: the computer where Omron Ethernet DAServer is running 
must be added to the IP Address Table. To add it, press "Insert" button. The "Insert 
Router's IP Address" dialog box appears: 
Enter the Node Number (in example 55) matching to the last octet in IP Address of 
computer where Omron Ethernet DAServer is running. Enter the IP Address of computer 
where Omron Ethernet DAServer is running (in example 195.2.103.55). Press "Ok". 
Insert the Node Number and IP Address of PLC. (In case of CS1-series PLCs the Node 
Number must match with settings on the rotary switch on the front side of Ethernet 
communication unit, IP Address – must match with settings of rotary switches on the back 
side of Ethernet communication unit). 