User Manual
27
RFID System
User's Manual
Section 2 Antennas with Built-in Amplifier
Section 2
Specifications and Performance
Operation Indicator
The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a
guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment.
Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does
not indicate a malfunction.
Differences between the V680-H01 and the V680-H01-V2
As shown in the following table, the V680-H01-V2 provides additional indicators.
Turn ON SW1-1(Antenna) when using the V680-CA1D/CA2D.
name Color Meaning
RUN Green Lit when the power is ON.
COMM Yellow Lit when a command is being sent.
NORM Green Lit when communications with a Tag are normal in Normal Communications Mode.
ERR Red Lit when an error occurs in communications with a Tag in Normal Communications
Mode.
CNT-TYPE Yellow Lit when in V680-CA@D Controller connection mode (SW1-1 setting: ON).
TAG-TYPE Yellow For expansion (not used): Always OFF.
LV6/7D Yellow Maintenance Mode: Lit at distance or speed level 6.
Normal Communications Mode: Lit when a write protection error occurs.
LV5/7A Yellow Maintenance Mode: Lit at distance or speed level 5 or higher.
Normal Communications Mode: Lit when an address error occurs.
LV4/76 Yellow Maintenance Mode: Lit at distance or speed level 4 or higher.
Normal Communications Mode: Lit when a Tag memory error occurs.
LV3/72 Yellow Maintenance Mode: Lit at distance or speed level 3 or higher.
Normal Communications Mode: Lit when a no Tag error occurs.
LV2/71 Yellow Maintenance Mode: Lit at distance or speed level 2 or higher.
Normal Communications Mode: Lit when a verification error occurs.
LV1/70 Yellow Maintenance Mode: Lit at distance or speed level 1 or higher.
Normal Communications Mode: Lit when a Tag communications error occurs.
display functions
V680-H01-V2 V680-H01
SW1-1: OFF SW1-1: ON no switch
RUN (POWER/COMM) OK OK OK
COMM (POWER/COMM) OK OK OK
NORM OK NO NO
ERR OK NO NO
CNT-TYPE OK OK NO
TAG-TYPE --- --- ---
LV6/7D OK NO NO
LV5/7A OK NO NO
LV4/76 OK NO NO
LV3/72 OK NO NO
LV2/71 OK NO NO
LV1/70 OK NO NO