User Manual
25
RFID System
User's Manual
Section 2 Antennas with Built-in Amplifier
Section 2
Specifications and Performance
Antennas with Built-in Amplifier
V680-H01-V2
General Specifications
Communications Specifications
Item Model V680-H01-V2
Ambient operating
temperature
−10 to 55°C (with no icing)
Ambient storage
temperature
−35 to 65°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 100 VDC) between connector terminals and the rear plate
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and the rear plate
Degree of protection IP63.(IEC60529); Mounting direction: Communications surface facing up
Dielectric strength
10 to 150 Hz, 0.35-mm single amplitude, acceleration: 50 m/s
2
, 10 sweeps in each of 3 axis directions
(up/down, left/right, and forward/backward) for 8 minutes each
Shock resistance
150 m/s
2
, 3 times each in 6 directions (Total: 18 times)
Cable length 0.5 m (use an extension cable to connect to the Controller up to 30.5 m)
LED indicators RUN, COMM, NORM, ERR, CNT-TYPE, TAG-TYPE, Error Code, Level
Weight Approx. 900 g
Item Model V680-H01-V2
Communications method Electromagnetic induction
Operating frequency 13.56 MHz ± 7KHz
Modulation ASK