RFID System V680 Series User's Manual for Amplifiers, Antennas, and ID Tags (EEPROM) Amplifier and Antennas V680-HA63A V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 ID Tags V680-D1KP52MT V680-D1KP66T V680-D1KP66MT V680-D1KP66T-SP V680-D1KP58HT Cat. No.
Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. Please observe the following items when using the RFID System. • Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. • Read and understand this manual before attempting to use the RFID System and use the RFID System correctly.
READ AND UNDERSTAND THIS DOCUMENT Product Overview Section 2 Specifications and Performance Section 3 Communications Specifications Section 4 Installation Section 5 Chemical Resistance RFID System V680-HA63A V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 V680-D1KP52MT V680-D1KP66T V680-D1KP66MT V680-D1KP66T-SP V680-D1KP58HT Amplifier Antenna Antenna Antenna Antenna Antenna ID Tag ID Tag ID Tag ID Tag ID Tag User's Manual Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Introdu
Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
Introduction Introduction Safety Precautions Alert Symbols for Safe Use The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of the V680-HS51, V680-HS52, V680-HS63, V680-HS65, V680-H01-V2, V680-HA63A, V680D1KP52MT, V680-D1KP66T, V680-D1KP66MT, V680-D1KP66T-SP, and V680-D1KP58HT. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual.
Introduction Introduction 2.
Introduction Introduction 5. China Amplifier Antenna CMII ID:2008DJ0884 V680-HA63A V680-HS51 CMII ID:2007DJ0577 V680-HA63A V680-HS52-R CMII ID:2007DJ0575 V680-HA63A V680-HS52-W CMII ID:2007DJ0571 V680-HA63A V680-HS63-R CMII ID:2007DJ0573 V680-HA63A V680-HS63-W CMII ID:2008DJ0141 V680-HA63A V680-HS65-R CMII ID:2008DJ0142 V680-HA63A V680-HS65-W 6. Korea Amplifier OMR-V680-HA63A V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 7.
Introduction Introduction 8. Hong Kong Amplifier LP407043 V680-HA63A Antenna V680-HS52 V680-HS63 9. Singapore Amplifier S0294-07 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 10.Malaysia Amplifier A011578 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 If the product is used in Malaysia, a label must be attached on-site to the side of the V680-HA63A. Please consult your OMRON sales representative for details. 11.
Introduction Introduction Precautions for Safe Use Be sure to observe the following precautions to ensure safe use of the Products. 1. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 2. Do not attempt to disassemble, repair, or modify any Product. 3. Tighten mounting screws securely. 4. Because a cable has a locking mechanism, make sure that it has been locked before using the cable. 5. Do not allow water or pieces of wire to enter from openings in the case.
Introduction Introduction Precautions for Correct Use Always observe the following precautions to prevent operation failures, malfunctions, and adverse effects on performance and equipment. 1. Installation Environment Do not use the Products in the following locations.
Introduction Introduction 3. Storage Do not store the Products in the following locations.
Introduction Introduction Meanings of Symbols 10 Meanings of Symbols Indicates particularly important points related to a function, including precautions and application advice. Indicates page numbers containing relevant information.
Introduction Introduction Table of Contents Safety Precautions 3 Regulations and Standards 3 Precautions for Safe Use 7 Precautions for Correct Use 8 Meanings of Symbols 10 Table of Contents 11 Section 1 Product Overview 13 Features 14 Product Configuration 15 Section 2 Specifications and Performance 17 Antennas with Separate Amplifier 18 Antennas with Built-in Amplifier 25 Amplifier 30 Tags 33 Section 3 Communications Specifications 43 Communications Distances 44 Communica
Introduction Introduction 12 MEMO RFID System User's Manual
Section 1 Section 1 Product Overview 14 Product Configuration 15 RFID System User's Manual Product Overview Features 13
Section 1 Product Overview Features The V680-series RFID System actively supports many different types of system, such as distributed-control Section 1 Features systems and many-product, small-lot production systems, with non-contact data communications using electromagnetic induction. Non-contact Data Communications The V680 Series uses electromagnetic induction to enable non-contact, bi-directional data communications between Antennas and Tags.
Section 1 Product Overview Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration Tags. Select the models suitable for the application.
Section 1 Product Overview Using a V680-H01-V2 Antenna with Built-in Amplifier Programmable Controller (SYSMAC CS/CJ Series) Section 1 Product Configuration Host device Personal computer RS-232C RS-422 RS-485 CS1W-V680C11 ID Controller ID Sensor Units V680-CA5D01-V V700-A40-W CJ1W-V680C11 V68 0C1 RUN1 ERC NOR ERP ERH T/R M/ER R TES T ON HEA D1 M Cable * Always use the specified Cable to connect a V680-H01-V2 Antenna.
Section 2 Specifications and Performance Section 2 18 Antennas with Built-in Amplifier 25 Amplifier 30 Tags 33 RFID System User's Manual Specifications and Performance Antennas with Separate Amplifier 17
Section 2 Specifications and Performance Antennas with Separate Amplifier V680-HS51 General Specifications Item Model V680-HS51 Section 2 Antennas with Separate Amplifier Ambient operating temperature −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min.
Section 2 Specifications and Performance V680-HS52 General Specifications Item Model V680-HS52-W (Standard cable, waterproof connector) V680-HS52-R (Flexible cable, non-waterproof connector) −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min.
Section 2 Specifications and Performance • V680-HS52-R 22.5 dia. Two toothed washers Two lock nuts Mounting Hole Dimensions (39.5) 35 dia. 30 14.5 dia. 16.5 dia. 7 30 47.6 50 57 65 RFID System User's Manual Insulation cover Connector 16.5 dia. Ferrite core Operation indicator Antenna 19.8 dia. Section 2 Antennas with Separate Amplifier 20 M22 × 1 50 Coaxial cable, 5.3 dia.
Section 2 Specifications and Performance V680-HS63 General Specifications Item Model V680-HS63-W (Standard cable, waterproof connector) −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60Hz for 1 min between cable terminals and case Degree of protection IP67.
Section 2 Specifications and Performance V680-HS63-R Antenna Ferrite core 6 30 53 RFID System User's Manual 50 Coaxial cable, 5.3 dia., standard length: 2 m Insulation cover 11 Operation indicator Note: Mounting Hole Dimensions Coil center 16.5 dia. 16.5 dia. 14.5 dia. 40 28±0.1 27 5 23 Section 2 Antennas with Separate Amplifier 22 5 (39.5) (Unit: mm) Connector Two, M4 or 4.5 dia.
Section 2 Specifications and Performance V680-HS65 General Specifications Item Model V680-HS65-W (Standard cable, waterproof connector) V680-HS65-R (Flexible cable, non-waterproof connector) −25 to 70°C (with no icing) Ambient storage temperature −40 to 85°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min.
Section 2 Specifications and Performance V680-HS65-R 5 4-4.5 dia. (Mounting holes) 50 5 Operation indicator (Unit: mm) 100 90±0.2 Ferrite core 50 Bushing 30 10 20 30 User's Manual 50 10 14 RFID System 16.5 dia. 14.5 dia. 16.5 dia. 100 90±0.2 Section 2 Antennas with Separate Amplifier 24 Connector (39.5) 25 Coaxial cable, 5.3 dia.
Section 2 Specifications and Performance Antennas with Built-in Amplifier V680-H01-V2 General Specifications Item Model V680-H01-V2 −10 to 55°C (with no icing) Ambient storage temperature −35 to 65°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 100 VDC) between connector terminals and the rear plate Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and the rear plate Degree of protection IP63.
Section 2 Specifications and Performance Dimensions MOUNTING SCREW HOLES (Unit : mm) Connector Vinyl Insulated Round Cord (5.8-dia.) (41/0.16-dia.) 2 Cores (17/0.08-dia.) 8 Cores Standard Length 0.5 m 142.5 235±0.2 Four, M4 or 4.5-dia. holes Twelve, Operation Indicator Four, 5-dia. holes (Mounting Holes) Communications sufrace 14 64.8 20-dia. 185 (25-dia.) 200 Ferrite Core 65 Section 2 Antennas with Built-in Amplifier 185±0.
Section 2 Specifications and Performance Operation Indicator name Color Meaning RUN Green Lit when the power is ON. COMM Yellow Lit when a command is being sent. NORM Green Lit when communications with a Tag are normal in Normal Communications Mode. ERR Red Section 2 Antennas with Built-in Amplifier Lit when an error occurs in communications with a Tag in Normal Communications Mode. CNT-TYPE Yellow Lit when in V680-CA@D Controller connection mode (SW1-1 setting: ON).
Section 2 Specifications and Performance Setting Switch Section 2 Antennas with Built-in Amplifier Setting switch protection cover Note: Please attach a setting switch protection cover after setting switch. Setting Function Default setting SW1-1 Controller selection OFF:V680-CA5D01-V@, CS1W-V680C11, or CJ1W-V680C11 ON: V680-CA1D/-CA2D OFF SW1-2 Reserved by System (Always set this Switch to OFF.) --- SW1-3 Reserved by System (Always set this Switch to OFF.
Section 2 Specifications and Performance Cables (V680-H01-V2 exclusive use) Specifications Item Model V700-A40-W Number of conductors 10 Insulation resistance 5 MΩ min. (at 500 VDC) between terminals and sheath Dielectric strength 500 VAC, 1 min Section 2 Antennas with Built-in Amplifier Dimensions Item Model Length (L1) Weight L1 V700-A40-W 2M V700-A40-W 5M V700-A40-W 10M V700-A40-W 20M V700-A40-W 30M Approx.2m Approx. 5 m Approx.10m Approx. 20 m Approx. 30 m Approx.
Section 2 Specifications and Performance Amplifier V680-HA63A General Specifications Item Model V680-HA63A Section 2 Amplifier Ambient operating temperature −10 to 55°C (with no icing) Ambient storage temperature −25 to 65°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between cable terminals and case.
Section 2 Specifications and Performance Nomenclature Antenna with Separate Amplifier connection port Operation indicators Section 2 Amplifier RUN COMM NORM ERR LV6/7D LV5/7A LV4/76 LV3/72 LV2/71 LV1/70 Controller connector Antenna Connection Port The Antenna connection port is connected a V680-series Antenna. Controller Connector The Controller connector is connected to Antenna connection port on the Controller. Operation Indicators (LEDs) Name Color RUN Green Lit when the power is ON.
Section 2 Specifications and Performance Cables (V680-HA63 exclusive use) Specifications Item Model V700-A43/V700-A44 Number of conductors 10 Insulation resistance 5 MΩ min. (at 500 VDC) between terminals and sheath Dielectric strength 500 VAC, 1 min Item Model Length (L1) Weight V700-A43 V700-A44 Approx.10m Approx. 20 m Approx. 700 g Approx.1,350 g L1±100 49 6 dia. 15 dia. 51 15.5 dia.
Section 2 Specifications and Performance Tags Specifications and Dimensions V680-D1KP52MT • General Specifications Model V680-D1KP52MT 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C) Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.
Section 2 Specifications and Performance V680-D1KP66T/66MT • General Specifications Item Model V680-D1KP66T V680-D1KP66MT Section 2 Tags Memory capacity 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C) Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.
Section 2 Specifications and Performance • Dimensions V680-D1KP66T/66MT Four, R4 34 Four, R3 25+0.2 32 Mounting Hole Dimensions 25+0.2 Two, M3 25+0.2 Section 2 Tags Two, 3.5 dia. Two, 6 dia. 32 25+0.2 3.5+0.1 34 Case material PPS resin V600-A86 Attachment Four, R5.5 25+0.2 Two, 4 dia. Two, M3 37 34 15 25+0.2 16 25+0.2 25+0.2 15 34 4 3.
Section 2 Specifications and Performance V680-D1KP66T-SP • General Specifications Item Model V680-D1KP66T-SP Memory capacity 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less) Section 2 Tags Memory longevity 100,000 times per block (25°C) Ambient operating temperature when communicating −25 to 70°C (with no icing) Ambient operating temperature when not communicating −40 to110°C (with no icing) Ambient storage temperature −40 to 110°C (with n
Section 2 Specifications and Performance V680-D1KP58HT • General Specifications Item Model V680-D1KP58HT 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 2 years after writing (85°C to 110°C) Total data backup time at high temperatures exceeding 110°C is 10 houres (See note.
Section 2 Specifications and Performance • Tag Heat Resistivity • Storing Tags under high temperatures will adversely affect the performance of the internal parts and the service life of the Tags. • An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after testing under the following test conditions • Heat cycle: Room temperature/200ÅãC, 30 minutes each for 2,000 cycles.
Section 2 Specifications and Performance • Dimensions V680-D1KP58HT (Unit: mm) 10±0.2 60 dia. 5° 5° 80 dia Section 2 Tags 14 dia Case material PPS resin Two, R2 The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. V680-A80 (Attachment) This Attachment is specifically designed to secure V680-D1KP58HT Tags to the workpiece. Applicable Tag model: V680-D1KP58HT 17 (Unit: mm) 20 dia. 12 dia. M12 3.2 dia. M12 11.
Section 2 Specifications and Performance Memory Map Data Address Section 2 Tags 0000 0001 H 0002 H 0003 H 03E6 H 03E7 H H User area 1 byte EEPROM is used as memory in the Tags. The memory capacity available to the user is 1,000 bytes, including 0000H to 0003H (the Write Protection Setting Area). The access to the memory is executed at every block. 1 block is 8 bytes (8 addresses).
Section 2 Specifications and Performance Write Protection Function The write protection function prevents important data, such as product information, stored in memory in a Tag from being inadvertently overwritten. After important data has been written to memory, it can be write-protected using the following method.
Section 2 Specifications and Performance MEMO Section 2 Tags 42 RFID System User's Manual