User's Manual
17
RFID System
User's Manual
Section 2 ID Sensor
Section 2
Part Names and Functions
Connected connector:CN1
A high-ranking equipment of PLC is connected.
Military Standard(MIL-C-83503) conforming connector(use connector: Type XG4A-2639-A and made in OMRON)
Connected connector:CN2
Connected connector:CN1
Viewed from the connecting side
Triangular mark
26
25
2
1
Pin No Signal name Lead wire color Description I/O
1 FG Shield Grownd to 100
: or less FG
2 --- --- --- ---
3 --- --- --- ---
4 NOISE_OUT Gray/Red Noise-sheck out put Output
5 0 V Blue Power input Power supply
6 24 VDC Brown Power input Power supply
7 PARITY Gray/White
Parity-check output(OFF when number,ON when odd number)
Output
8 INHIBIT/TRIG Red
Inhibit input (AUTO)
Input
Trigger input (SYNC)
9 NORM/STRB Light green
Read normal termination output (for OUTPUT MODE1)
Output
Strobe output (for OUTPUT MODE2)
10 ERR Violet Error output (see note1.) Output
11 OD9 White/Red Read data input bit10 Output
12 OD8 White/Black Read data input bit9 Output
13 OD11 White/Yellow Read data input bit12 Output
14 OD10 White/Green Read data input bit11 Output
15 OD13 White/Blue Read data input bit14 Output
16 OD12 White/Brown Read data input bit13 Output
17 OD15 Gray/Black Read data input bit16 Output
18 OD14 White/Orenge Read data input bit15 Output
19 OD1 Yellow Read data input bit2 Output
20 OD0 Green
Read data input bit1
Output
Agreement output (Verify)
21 OD3 Black Read data input bit4 Output
22 OD2 White Read data input bit3 Output
23 OD5 Bitter orange Read data input bit6 Output
24 OD4 Gray Read data input bit5 Output
25 OD7 Pink Read data input bit8 Output
26 OD6 Light blue Read data input bit7 Output
Note 1. Only the error output line is active when the singnal level is low(OFF). It is set to ON when the power is turned on.
The error output line thus also serves as a RUN output line for powwer-on verification.