User's Manual
59
RFID System
User's Manual
Section 5 I/O Specifications
Section 5
I/O Settings and Control Methods
Using V600-compatible Mode
BIT SET
Master Unit to DeviceNet Remote ID Controller
DeviceNet Remote ID Controller to Master Unit
Signal Bit length Value Description
WRITE/READ 1 1 Write operation
WT_MODE1 1 1 BIT WRITE
WT_MODE2 1 0 BIT SET
WT_BYTE 1 0 or 1 If the bit is 0, the operation will be 8-bit write, and 16-bit write if the bit
is 1.
WT_AREA 1 0 or 1 Write Address Switching When Using 8-bit Write Operation
If the bit is 0, the data for ID0 to 7 will be written to the ID Tag, and
data for ID8 to 15 will be written to the ID Tag if the bit is 1.
OD 32 --- BIT SET data
Valid to the number of BIT SET data bytes.
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 Set to 1 if the command ends in an error.
ID 24 0000···· Filled with zeroes.