User's Manual
58
Section 5 I/O Specifications
RFID System
User's Manual
Section 5
I/O Settings and Control Methods
NOISE MEASUREMENT
Master Unit to DeviceNet Remote ID Controller
DeviceNet Remote ID Controller to Master Unit
Mode: 4-byte Access
Mode: 26-byte or 58-byte Access
Master Unit to DeviceNet Remote ID Controller Settings Example
Signal Bit length Value Description
CMD0 to
CMD3
4 0111B NOISE MEASUREMENT
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 Set to 1 if the command ends in an error.
XXX_ERR 10 0 or 1 The bit corresponding to error completion will be 1, and the error
details will be displayed.
R-DATA 32 --- Result of noise measurement
05 hex: Average noise level
04 hex: Maximum noise level
07 hex: Minimum noise level
06 hex: Always 00H
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 Set to 1 if the command ends in an error.
XXX_ERR 10 0 or 1 The bit corresponding to error completion will be 1, and the error
details will be displayed.
R-DATA 32 --- Result of noise measurement
07 hex: Average noise level
06 hex: Maximum noise level
09 hex: Minimum noise level
08 hex: Always 00H
1514131211109876543210
Bits
CIO
+0
0000000000000000
CIO
+1
CIO
+2
CIO
+3
*******011110000
Change according to settings.
NOISE MEASUREMENT Fixed
Fixed
Fixed
0000000000000000
Fixed
0000000000000000
Fixed