User's Manual
57
RFID System
User's Manual
Section 5 I/O Specifications
Section 5
I/O Settings and Control Methods
DATA FILL
Master Unit to DeviceNet Remote ID Controller
DeviceNet Remote ID Controller to Master Unit
Master Unit to DeviceNet Remote ID Controller Settings Example
Example: Filling with FFH to 16 bytes from Address 0006H (2 Blocks × 8 Bytes/Block)
Signal Bit length Value Description
CMD0 to
CMD3
4 0100B DATA FILL
LEN0 to LEN7 4 1H to FH
4-byte mode
Number of blocks to process (specified number of blocks x 8 bytes)
If the number of blocks is 0, all memory will be selected.
8 00H to FFH
For 26-byte or 58-byte
Access Mode
ADDR0 to
ADDR15
16 0000H to FFFFH DATA FILL start address
OD 32 00H to FFH DATA FILL data
Data between OD1 and OD3 is invalid.
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 Set to 1 if the command ends in an error.
XXX_ERR 10 0 or 1 The bit corresponding to error completion will be 1, and the error details
will be displayed.
ID 32 Disabled ID Tag memory cannot be rewritten.
1514131211109876543210
Bits
CIO
+0
0000000000000110
CIO
+1
CIO
+2
CIO
+3
*******001000010
0000000011111111
0000000000000000
Change according to settings.
DATA FILL 2 bytes
Address 0006
H
Fixed
Fixed FFH
Fixed Fixed