Section 5 I/O Specifications
RFID System
User's Manual
Section 5
I/O Settings and Control Methods
BIT CLEAR
Master Unit to DeviceNet Remote ID Controller
DeviceNet Remote ID Controller to Master Unit
Signal Bit length Value Description
CMD0 to
CMD3
4 0011B BIT Clear
LEN0 to LEN7 8 1 to 4 Number of BIT CLEAR data bytes
A specification error will occur if 0H, or 5H or higher is specified.
ADDR0 to
ADDR15
16 0000H to FFFFH BIT CLEAR start address
OD 32 --- BIT clear data
Valid to the number of BIT CLEAR data bytes.
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 Set to 1 if the command ends in an error.
XXX_ERR 10 0 or 1 The bit corresponding to error completion will be 1, and the error
details will be displayed.
ID 32 --- Write data