User's Manual
53
RFID System
User's Manual
Section 5 I/O Specifications
Section 5
I/O Settings and Control Methods
Detailed Command Settings
Using 4-byte, 26-byte, and 58-byte Access Modes
DATA READ
Master Unit to DeviceNet Remote ID Controller
DeviceNet Remote ID Controller to Master Unit
Master Unit to DeviceNet Remote ID Controller Settings Example
Example: Reading 2 Bytes of Data from Address 0120H.
Signal Bit length Value Description
CMD0 to 3 4 0000B Data read
LEN0 to LEN7 8 01H to 3AH Number of bytes to process (no ASCII/hex conversion)
01H to 74H Number of bytes to process (ASCII/hex conversion)
ADDR0 to 15 16 0000H to FFFFH Read start address
Signal Bit length Value Description
NORM 1 0 or 1 Set to 1 when operation is ended normally.
ERR 1 0 or 1 The corresponding bit is set to 1 if the command ends in an error.
ERR_SUB* 1 0 or 1 The bit corresponding to error completion will be 1, and the error
details will be displayed.
ID 32 --- Read data (4-byte Access Mode)
240 --- Read data (26-byte Access Mode)
464 --- Read data (56-byte Access Mode)
1514131211109876543210
Bits
CIO
+0
0000000100100000
CIO
+1
CIO
+2
CIO
+3
*******000000010
0000000000000000
0000000000000000
Change according to settings.
DATA Read 2 bytes
Address 120
Fixed
Fixed
Fixed