Section 5 I/O Specifications
Section 5
I/O Settings and Control Methods
V600-compatible Mode
The DeviceNet Remote ID Controller is allocated 32 inputs (2 words) and 32 outputs (2 words) in the
PLC. The inputs and outputs that are allocated (X words, Y words) depend on the node address set for
the Master and the DeviceNet Remote ID Controller.
Master Unit to Remote ID Controller
Remote ID Controller to Master Unit
Normal Completion
Completion with Error
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X ID7 ID6 ID5 ID4 ID3 ID2 ID1 ID0
(X+1) ID15 ID14 ID13 ID12 ID11 ID10 ID9 ID8
(X+2) ADDR7 ADDR6 ADDR5 ADDR4 ADDR3 ADDR2 ADDR1 ADDR0
(X+3) INHIBIT/
TRG
WRITE/
READ
WT_AREA WT_BYTE WT_MODE1 WT_MODE0
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Y OD7 OD6 OD5 OD4 OD3 OD2 OD1 OD0
(Y+1) OD15 OD14 OD13 OD12 OD11 OD10 OD9 OD8
(Y+2) EXTOD23 EXTOD22 EXTOD21 EXTOD20 EXTOD19 EXTOD18 EXTOD17 EXTOD16
(Y+3) HS NOMAL ERROR
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Y
(Y+1)
(Y+2) Hard_ERR 7E,79_ERR 7D_ERR 7A_ERR 72_ERR 71_ERR 70_ERR
(Y+3) HS NOMAL ERROR