I/O Allocation Table
Mode: 4-byte Access
The DeviceNet Remote ID Controller is allocated 64 inputs (4 words) and 64 outputs (4 words) in the
PLC. The inputs and outputs that are allocated (X words, Y words) depend on the node address set for
the Master and the DeviceNet Remote ID Controller.
Master Unit to Remote ID Controller
Remote ID Controller to Master Unit
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X INHBIT/TRG AUTO/
SYNC
OUTPUTTIM
E
W
PROTECT
VERIFY HIGHSPD ASCII/HEX
(X+1) CMD3 CMD2 CMD1 CMD0 LEN3 LEN2 LEN1 LEN0
(X+2) ADDR7 ADDR6 ADDR5 ADDR4 ADDR3 ADDR2 ADDR1 ADDR0
(X+3) ADDR15 ADDR14 ADDR13 ADDR12 ADDR11 ADDR10 ADDR9 ADDR8
( X + 4) W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA
( X + 5) W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA
( X + 6) W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA
( X + 7) W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA W-DATA
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Y BUSY RUN
(Y+1) ERROR NORM
(Y+2) SYS_ERR CMD_ERR
(Y+3) 7F_ERR 7E79_ERR 71_ERR 7D_ERR 7A_ERR 70_ERR 72_ERR
( Y + 4) R_ DATA R _DATA R _DATA R_ DATA R _DATA R _DATA R _DATA R_ DATA
( Y + 5) R_ DATA R _DATA R _DATA R_ DATA R _DATA R _DATA R _DATA R_ DATA
( Y + 6) R_ DATA R _DATA R _DATA R_ DATA R _DATA R _DATA R _DATA R_ DATA
( Y + 7) R_ DATA R _DATA R _DATA R_ DATA R _DATA R _DATA R _DATA R_ DATA