V680-D1KP66MT
Mount the ID Tag to metal using M3 pan-head screws
from the marked side. Tighten the screws to a torque
of 0.3 to 0.5 N·m.
V680-D1KP66T-SP
Mount the ID Tag using M5 screws and washers. Tighten the screws to a torque of 1.2 N·m or less. The
installation direction of ID Tags is not restricted by the travel direction in respect to the Antenna.
V680-D2KF52M
Tag Installation
Mount Tags as shown in the diagram on the right.
The epoxy adhesives listed in the following table are
recommended for the given temperature ranges.
When embedding the V680-D2KF52M into a metal surface, use the V680-HS51/HS-52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
Ambient operating
temperature
Product name Manufacturer
40 to 70°C
Two-part Epoxy-compound
Resin:
TB2001 (main agent)/TB2105C
(curing agent)
Three Bond Co.,
Ltd.
One-part Moisture-curing Elastic
Adhesive
TB1530
Three Bond Co.,
Ltd.
40 to 85°C
One-part Epoxy Resin: TB2285 Three Bond Co.,
Ltd.
Two-part Epoxy Resin: TB2087 Three Bond Co.,
Ltd.
Two, M3
Mounting Hole Dimensions
Marked
side
25
±0.2
25±0.2
3 pan-head screw
Two, M5
Mounting Hole Dimensions
80
±0.2
R0.2 max.
Marked side
Marked side
8.1
+0.1
0
dia.
5
+0.1
0