User's Manual

44
Section 4 Installing ID Tags
RFID System
User's Manual
Section 4
Installation, Connections, and Wiring
Installing ID Tags
V680-D1KP52MT
Tag Installation
Mount Tags as shown in the diagram on the right. The epoxy
adhesives listed in the following table are recommended for the
given temperature ranges.
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51/-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
V680-D1KP66T
Mounting on Non-metallic Material
Mount the ID Tag using M3 pan-head screws from the
marked side.
Tightening torque: 0.3 to 0.5 N·m
Mounting on Metal
The communications distance will decrease if there is
metal at the back of the V680-D1KP66T ID Tag.
If the ID Tag is mounted to metal, use the separately
sold Special Attachment (V600-A86) or a non-metallic
spacer (e.g., plastic or resin).
Refer to Effect of Metal behind Tags (Reference) in Section 6 Appendices for information on the effect of metal behind
the V680-D1KP66T.
p.107
Ambient
operating
temperature
Product name Manufacturer
40 to 70°C
Two-part Epoxy-compound Resin:
TB2001 (main agent)/TB2105C (curing agent)
Three Bond
Co., Ltd.
One-part Moisture-curing Elastic Adhesive
TB1530
Three Bond
Co., Ltd.
40 to
150°C
One-part Epoxy Resin: TB2285 Three Bond
Co., Ltd.
Two-part Epoxy Resin: TB2087 Three Bond
Co., Ltd.
R0.2 max.
Marked side
Marked side
8.1
+0.1
0
dia.
5
+0.1
0
Two, M3
Mounting Hole Dimensions
Marked side
25
±0.2
25
±0.2
M3 pan-head screw
Two, M3
Mounting Hole Dimensions
Marked
side
25
±0.2
25
±0.2
Attachment (V600-A86)
M3 pan-head screw