Names and Functions of Components
Mode Switch
The mode switch sets the DeviceNet Remote ID Controller’s operating mode.
Turn the power OFF before setting the mode switch. The mode that is set when the power is turned ON will be used.
Node Address Switches
The node address switches set the node address of the DeviceNet Remote ID Controller.
Node addresses between 64 and 99 can be set using the Configurator. Refer to the DeviceNet DRT2-series Slave
Manual (Cat. No. ntlp) for information on the setting procedure.
Turn the power OFF before setting the node address switches. The node address that is set when the power is turned
ON will be used.
Mode Symbol Description
0 4CH 4-byte access mode
1 16CH 26-byte access mode
2 32CH 58-byte access mode
3 SYNC1 V600-compatible Trigger Mode, 100-ms output time
4 SYNC2 V600-compatible Trigger Mode, 500-ms output time
5 AUTO1 V600-compatible Auto Mode, 100-ms output time
6 AUTO2 V600-compatible Auto Mode, 500-ms output time
7 TEST Test mode (checking operation alone)
8 NOISE Noise measurement mode (measuring the noise environment around the Antenna)
9 - Mode setting error
Item Description
Setting method Two-digit decimal number
The left rotary switch sets the 10s digit, and the right rotary switch set the 1s digit.
Setting range 00 to 63