User's Manual

37
5-3 Command format (When the communication mode with the host is the polling mode)
a) The stop, write, same data write, and tag write protect commands are always in the realtime mode.
b) Read
Command A
Specifies the bank and page to be read.
CR
Page Specification
Termina-
tor
‘31’
@
ADR
Status
Header
Command
A/H
Commu-
nication
Mode
Bank
Specification
ADR represents the address number expressed by '30-39' and '41-46' in ASCII converted from the
hexadecimal 0-F. Send (00) h for the Status in 1:1 communication in general.
Response A to command A
@
ADR
Status
CR
Header
Termina-
tor
Command B
This command is sent to request for the tag data read verify.
@
ADR
Status
CR
Header
Termina-
tor
ADR represents the address number expressed by '30-39' and '41-46' in ASCII converted from the
hexadecimal 0-F. Send (00) h for the Status in 1:1 communication in general.
Response B to command B
The exit code ('00' in normal state) and the read data are returned. The read data is returned in
ascending sequence starting from the smallest number of the specified pages. If an error occurs, the
error code is returned as the exit code.
Header
Exit Code
@
ADR
Status ‘00’
Read Data
Ter m in a-
tor
Data
1
···· ···· ····
Data
n
CR
2. Test
This is a command to perform a test on host communications which allows communication tests on an
applicable address.
As is the case with the command Read, the response B is returned via the response A and command B.
The response B has the same contents as those of command A.
When a command is received normally, the ACK
flag of the Status box is received as '1'.