User Manual
Table Of Contents
- V670 Series
- Introduction
- Contents
- Structure of This Manual
- Chapter 1 Features and System Configuration
- Chapter 2 Specifications and Performance
- Chapter 3 Setting and Installation
- Chapter 4 Functions
- Chapter 5 Control From Host Device
- Chapter 6 How to Use Self-Execution Mode
- Chapter 7 How to Use Programming Console
- Chapter 8 From Startup to Run
- Chapter 9 Characteristic Data Depending on Operating Condition (Reference)
- Appendix
5-6 Communication Command
5-15
5-6-6 Tag Function Designation (TF)
Sets/cancels Write Protect etc. to a tag.
Example: Setting Write Protect function of the addresses 0010h to 001Fh to a tag
(Single trigger)
Setting protect area information
Sent data: WTSTH 1 0 0 0 0 0 4 0 0 1 0 0 0 1 F * [CR]
Received data: WT 0000*[CR]
Setting protect function
Sent data: TFSTP 1 * [CR]
Received data: TF 0 0 0 0 * [CR]
Communication designation Specifies how to communicate with a tag. For details, refer to the communication desig-
nation list.
Process designation Sets/cancels a function.
"P": Sets Protect
"R": Cancels
Antenna designation Fixed to "1".
Correct Usage
For details of Write Protect, refer to "4-6 Write Protect Function".
<Command>
Command
code
"TF"
Communication
designation
Process
designa-
tion
Antenna
designa-
tion