User Manual
Table Of Contents
- V670 Series
- Introduction
- Contents
- Structure of This Manual
- Chapter 1 Features and System Configuration
- Chapter 2 Specifications and Performance
- Chapter 3 Setting and Installation
- Chapter 4 Functions
- Chapter 5 Control From Host Device
- Chapter 6 How to Use Self-Execution Mode
- Chapter 7 How to Use Programming Console
- Chapter 8 From Startup to Run
- Chapter 9 Characteristic Data Depending on Operating Condition (Reference)
- Appendix
For the safety, be sure to follow the instructions below:
1. Do not operate this device in any flammable, explosive or corrosive gas environment.
2. Do not disassemble, repair nor remodel this device.
3. Tighten the base lock screws and terminal block screws completely.
4. Be sure to use wiring crimp terminal of a specified size.
5. If any cable has a locking mechanism, be sure to check that it has been locked before using it.
6. The DC power supply must meet the following items:
(1) Such DC power supply must be used for the V670 Series only and must not be connected to any other devices nor apparatuses.
(2) Voltage of such DC power supply must be within the specified rating (24 VDC+10%-10%).
7. Be sure to follow any other warnings, cautions and notices mentioned in this manual.
1. Do not install Model V670-CD1D in the following areas:
• Place exposed to the direct sunlight.
• Humid place where moisture condensation may occur.
• Place affected by vibration or impact.
2. Preliminary check of installation site.
This device uses the frequency band 13.56 MHz to communicate with a tag. This frequency band 13.56 MHz is used also as the ISM
band (one of frequencies assigned to medical or industrial heater; an application must be filed for installation). So, such heater may
affect the communication with a tag or may damage the tag, if the heater is located near this device. If you must this device near such
heater, we would like you to check the influence in advance. To minimize general influence of noise, follow the instructions below:
• Ground any metallic material located around this device according to Class D (Class III).
• Wire this device keeping away from high voltage and heavy current.
3. Be sure to ground any ground terminal according to Class D (conventional Class III). Otherwise, performance may deteriorate.
4. Cleaning of Model V670-D13F03, Model V670-H11 and Model V670-CD1D.
• Do not use any thinner. Resin material and case paint are dissolved by thinner.
Notes on safety
Notes on usage