3-1 Controller
3-2
3-1-1-2 How to Set
Set the switch using the screwdriver which comes with the controller as shown below.
• Setting a node number
Turn clockwise or counterclockwise.
3-1-1-3 Setting List
Set the switches according to the list below. (The switches are set to a default value at shipment from a factory.)
Name Function Default Value
SW1 1: Node number setup switch used in N protocol. 00
SW2
SW3-1
Switch to change a function of input terminal (RST/IN).
Reset input
SW3-2 Switch to set an operation mode at startup.
Command execution mode
SW3-3 Switch to enable or disable verification at writing. Disabling verification
SW3-4 Switch to set a protocol (1:1 / 1:N). 1:1 protocol
SW3-5 Set to OFF. OFF
SW3-6
SW3-7
SW3-8
SW4-1 Switch to set a communication speed of RS-232C. 9600 bps
SW4-2
SW4-3 Switch to set data length of RS-232C. 7 bits
SW4-4 Switch to set parity of RS-232C. Even parity
SW4-5
SW4-6 Switch to set stop bit of RS-232C. 2 bits
SW4-7 Set to OFF. OFF
SW4-8
• Setting a dip switch
Set to the right or left.
(Left)
(Right)