Datasheet
9
2JCIE-BL Environment Sensor
Characteristics
*1. The Bluetooth
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON Corporation is under license.
*2. Information on UV Index is just for reference. And it may not be the same as
that issued by public institutions.
*3. Information for heat stroke and discomfort index are only guidelines to be used for
air conditioning and physical condition management. An individual difference
and physical condition will greatly affect an individual feeling. Sensor output is not to be used for determining the presence of symptoms. Use only as a guideline.
Warning levels for heat stroke may not be the same as those issued by public institu
tions.
*4. Communication distance and battery life may vary according to obstacles between the communicat
ion equipment, radio wave conditions.
*5. These values are specified under standard test condition, an
d do not guarantee the performance under the complex conditions.
*6. These types of output are provided for referential use only, a
nd these values do not guarantee the normal operation within that range.
Dimensions (Unit: mm)
Item Measurable range Accuracy (Vcc = 3.0 V, Ta = 15 to 35°C if not specified)
*5
Temperature -10 to 60°C ±2°C
Humidity 30 to 85%RH ±5%RH
Light 10 to 2,000 lx ±100 lx
UV Index 0 to 11 For reference
*2 *6
Barometric pressure 700 to 1,100 hPa ±4 hPa
Sound noise 37 to 89 dB For reference
*6
Battery cover
15
39
46
Window
Vent hole
CAD Data
2JCIE-BL01
1.2
±0.2
φ20
24
±0.5
20
±0.2
6.5
±0.2
23
±0.2
27.2
±0.5
1
±0.2
(3)
R1
2
Vcc (+)
Vss (-)Insulation
Vss (-)
2JCIE-BL01-P1
CAD Data