Datasheet
14
2JCIE-BU Environment Sensor (USB Type)
Characteristics
*1. 3-axis acceleration values can only be obtained in the specified operation mode. For details, refer to the User’s Manual.
*2. eTVOC (equivalent Total Volatile Organic Compounds) refers to the total concentration of volatile organic compounds in a room environment. Output TVOC values
will be higher or lower depending on the type of volatile organic compound. Also, if continuously operated in high-temperature and high-humidity environments,
sensitivity for eTVOC values may decrease.
*3. Information for heat stroke and discomfort index are only guidelines to be used for air conditioning and physical condition management. An individual difference
and physical condition will greatly affect an individual feeling. Sensor output is not to be used for determining the presence of symptoms. Use only as a guideline.
Warning levels for heat stroke may not be the same as those issued by public institutions.
*4. SI (Spectral Intensity) values corresponds to the destructive energy seismic motions exert on a structure.
*5. The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON Corporation is under license.
*6. Communication distance may vary according to obstacles between the communication equipment, radio wave conditions.
*7. Performance values are obtained based on the various conditions of individual tests, and do not guarantee the values obtained under combined conditions for rated
values and performance values.
*8. Reference output values are provided for reference only, and do not guarantee that operation will always take place normally within that range.
*9. In a VOC environment outside the detection range, the output values of eTVOC and eCO2 may output -32767.
Dimensions (Unit: mm)
Item Measurable range Accuracy (Vcc = 5.0 V, Ta = 15 to 35°C if not specified) *7
Temperature −10 to 60°C ±2°C
Humidity 30 to 85%RH ±5%RH
Light 10 to 2000 lx ±100 lx
Barometric pressure 700 to 1100 hPa ±4 hPa
Sound noise 40 to 94 dB For reference *8
3-axis acceleration −2000 to 2000 gal For reference *1, *8
eTVOC 0 to 29206 ppb For reference *2, *8, *9
12
29.1
14.9
12
4.5
7
Vent hole
Vent hole
Window
LED indicator
CAD Data
● Main unit
2JCIE-BU01
17.5
±0.5
8.9
±0.5
18.9
±0.5
Attaching the filter cap Precautions when attaching the filter cap
Sensor body
Filter cap
Sensor
illumination window
Filter (both sides)
Make sure that there is no gap between
the sensor body and the cap.
Correct Wrong Correct Wrong
Make sure that the sensor illumination
window on the body and the cap are
not misaligned.
Location to attach the
double-sided tape
* Do not touch the filter attached inside
the filter cap.
* Cover the sensor with the filter cap
from above by slightly pushing and
widening the lower part of the filter
cap.
* Double-sided tape is recommended
to attach the filter cap firmly.
● Accessory (filter cap)
2JCIE-BU01-FL1
CAD Data