User Manual

Section 5 SETTING ADDITIONAL FUNCTIONS
Section 5
Setting Conditions Related to Bank
95
ZFV-C
User’s Manual
Clearing Banks
“Clearing” deletes the settings of the selected bank number.
X MENU mode-[SYS1]-[BANK SET]-[CLEAR]
[SYS1], [SYS2] settings and RUN mode display settings will not be cleared.
Setting the Bank Switching Method
Select how to switch banks.
X MENU mode-[SYS1]-[BANK SET]-[SWITCH]
Switching to Another Bank p.58
To switch a bank using a command via USB/RS-232C, select [SWITCH]-[KEY].
Settings Description
EXECUTE Executes clear.
CANCEL Cancels clear.
Setting Description
KEY (default) Banks are switched by the control keys on Amplifier Unit.
I/O Banks are switched by the control keys on Amplifier Unit and by external sig-
nals.