Section 4 SETTING OF INSPECTION CONDITION
Section 4
Inspecting by Count (COUNT)
79
ZFV-C
User’s Manual
Adjusting the threshold level
CUSTOM Menu
Items that can be customized
Items related to edge detection
Set the direction in which edges are searched and the density level.
Setting item Range Details of Adjustment
Count 0 to 255 Threshold level for counting.
Edge level 0 to 100 This is the density level judged to be an edge.
Adjust this level when measurement is unstable.
p.73
Items that can be customized Page
Items related to
edge detection
Selecting the color of edge p.80
Selecting the edge detection direction p.80
Items related to
color
Changing the color mode (default: [FILTER]) p.74
Changing the filter color (only when [FILTER] is selected in [COL MODE]) p.65
Changing Brightness during teaching (only when [PICKUP] is selected in [COL
MODE])
p.65
ADJ
RUNMENU
COUNT
OK
5
L:[ 5] H:[ 5]
COUNT
OK
:
EDGE LEV: [ 50]
LEV CHANGE
Adjustment of
count
Switching to
ADJ mode
Measured
values
UP/DOWN keys: Change values.
Lower limit
Upper limit
Edge level
Adjustment of
edge level
UP/DOWN keys: Change values.
When edge detection direction is
LEFT/RIGHT keys: Change values.
When edge detection direction is
+++++
EDGE MODE: DARK
DIRECTON:
Example)
To detect this number