Section 3 FUNCTIONS AND OPERATIONS TO BE USED
ZFV-C
User’s Manual
Section 3
Switching the Display Content
Switching the Display Content
Display contents on the LCD monitor can be changed in the RUN mode. Content is
switched in the following order each time the TEACH/VIEW key is pressed. Display the
measured values suitable for your application.
The measurement time differs according to the type of display image. The measurement time for “only
image display” is the fastest. The number in parentheses ( ) serves as a guideline when “only image dis-
play” is taken as the reference.
When the image is switched during measurement, the measurement time changes. For this reason,
monitor the ENABLE signal, wait for the ENABLE signal to turn ON, and then input the TRIG signal.
In the displays showing an image, the image type (color/monochrome) is switched each time the [A]
function key is pressed.
SCORE
+
+
+
JG
SCORE
JG
SCORE
TH
AVE
DRANGE
MCONT
NG%
TIME
:
:
:
:
:
:
:
:
OK
98
60
0
0-100
2
1.000
144
98
SEARCH
OK
SEARCH
OK
SEARCH
OK
SEARCH
OK
SEARCH
OK
SEARCH
OK
60
98
TH
:
:
:
:
Measurement
result (*3)
Teaching area
Teaching area
and Measure-
ment result (*1)
Teaching area and
control bar (*2)
Enlargement of mea-
surement result and
control bar (*2)
(*1) In the case of [BRIGHT], the display can be switched (average density value, density distribution value)
by the LEFT/RIGHT keys.
(*2) The control bar shows the measurement result and judgment threshold value.
(*3) The measurement time (TIME) indicated here is the shortest measurement time in “only image display”.