User Manual

Section 7 APPLICATION AND SETTING
Section 7
Inspecting Entry of Workpieces of Wrong Color (HUE)
157
ZFV-C
User’s Manual
Adjusting the Inspection Area
5. Select [REG.] and press the SET Key.
6. Adjust the size of the inspection area and
press the SET Key.
7. Adjust the position of the inspection area
and press the SET Key.
Move the green frame so that the target is cen-
tered in the inspection area.
Registering the Reference Workpiece
8. Press the TEACH/VIEW key.
“+” mark will appear at the center of the
inspection area.
Teaching is completed when the “+” mark dis-
appears.
Checking Operation
9. Switch the mode switch to “ADJ mode”.
10.
Check the measurement results displayed
on the LCD monitor.
TEACH/HUE
ITEM REG.
TEACH/REG.
SIZE
Zooms in/out
in vertical
direction.
Zooms in/out
horizontal
direction.
Vertical
direction
Horizontal
direction
TEACH/REG.
MOVE
TEACH/HUE
ITEM REG.
ADJ
RUNMENU
HUE OK
15
TH: [10]