Section 5 SETTING ADDITIONAL FUNCTIONS
Section 5
Setting for Amplifier Unit Gang-Mount
111
ZFV-C
User’s Manual
Specifying the Amplifier Unit to Input the Trigger
Set whether or not to input the TRIG signal to an Amplifier Unit.
X MENU mode-[SYS2]-[LINKSET]-[TRIG]
Setting the Presence of Sensor Head
Set whether or not a Sensor Head is connected.
X MENU mode-[SYS2]-[LINKSET]-[HEAD]
Setting Output Content
Set the output content of the measurement result output cable.
This item is displayed only the Amplifier Unit whose [TRIG/TRIG] setting is set to [I/O].
X MENU mode-[SYS2]-[LINKSET]-[OUTPUT]
Output image p.115
Setting Details
I/O (default) Set to only the Amplifier Unit to which the TRIG signal is to be input.
LINK Synchronizes to the TRIG signal from the Amplifier Unit gang-mounted on the
right side.
All the Amplifier Units except for the rightmost one are set to [LINK] automati-
cally.
Setting Details
USE (default) Select this for Amplifier Unit to which a Sensor Head is currently connected.
Measurement is performed using the input image from the currently connected
Sensor Head.
NOT USE Select this for Amplifier Unit to which a Sensor Head is currently not con-
nected.
Measurement is performed from the image transferred from the Sensor Head
gang-mounted on the right side.
Setting Details
ALL The measurement results of all gang-mounted Amplifier Units are integrated,
and output as an overall judgment result.
EACH (default) The measurement result of each Amplifier Unit is output from the respective
Amplifier Unit.