Datasheet

C-2 Vision Systems
Specifications
Sensor Heads
Item ZFV-SC10
(Narrow View)
ZFV-SC50/SC50W
(Standard View)
ZFV-SC90/SC90W
(Wide View)
ZFV-SC150/SC150W
(Ultra Wide View)
Setting distance (L)
34 to 49 mm (variable) 31 to 187 mm (variable)
67 to 142 mm (variable) 115 to 227 mm (variable)
Detection range (H × V)
5 × 4.6 mm to 9 × 8.3 mm
(variable)
10 × 9.2 mm to 50 × 46 mm
(variable)
50 × 46 mm to 90 × 83 mm
(variable)
90× 83 mm to 150 × 138 mm
(variable)
Relation between setting
distance and
detection range
Built-in lens
Focus: f15.65
Focus: f13.47 Focus: f6.1
Object lighting method
Pulse lighting
Object light source
8 white LEDs 36 LEDs 20 white LEDs 72 white LEDs
Lightning I/F (Option)
None Yes None
Sensing element
1/3-inch CCD
Shutter
Electronic shutter, shutter time: 1/500 to 1/8,000
Power supply voltage
15 VDC (Supplied from
Amplifier Unit.)
15 VDC, 48 VDC (Supplied from Amplifier Unit.)
Current consumption
Approx. 200 mA Approx. 350 mA [15 V: approx. 150 mA, 48 V: approx. 200 mA]
(Including the current consumed when external light is connected)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destructive)
10 to 150 Hz, 0.35 mm single amplitude, 10 times each in X, Y, and Z directions for 8 min
Shock resistance
(destructive)
150 m/s
2
, three times each in six directions (up/down, left/right, forward/backward)
Ambient temperature
Operating: 0 to +40 °C, Storage: –25 to +65 °C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere
Must be free of corrosive gas.
Connection type
Prewired, Standard cable length: 2 m
Degree of protection
(
IEC 60529)
IP65 ZFV-SC___: IP65
ZFV-SC___W: IP67
Material
Case: ABS, Mounting bracket: PBT
Weight
Approx. 200 g
(including mounting bracket
and cord; packaged
condition: approx. 300 g)
Approx. 270 g
(including mounting bracket
and cord; packaged
condition: approx. 350 g)
Approx. 300 g
(including mounting bracket
and cord; packaged
condition: approx. 380 g)
Approx. 600 g
(including mounting bracket
and cord; packaged
condition: approx. 780 g)
Accessories
Mounting bracket
ZFV-XMF (1),
Ferrite core (1),
Instruction sheet
Mounting bracket
ZFV-XMF2 (1),
Ferrite core (2),
Warning label (1)
Instruction sheet
Mounting bracket
ZFV-XMF2 (1),
Ferrite core (2),
Warning label (1)
Instruction sheet
Ferrite core (2),
Instruction sheet
LED class
*1
Class 1 Class 2 Class 2 Class 1
*1.
Applicable standards: IEC60825-1: 1993 +A1:1997 +A2:2001, EN60825-1:1994 +A:2002 +A:2001
Detection
range
(V)
(H)
Setting distance (L)
49 mm
34 mm
5 mm 9 mm
Detection range(H)
10 mm
187 mm
31 mm
50 mm
Setting distance (L)
Detection range (H)
50 mm
142 mm
67 mm
90 mm
Detection range (H)
Setting distance (L)
90 mm
227 mm
115 mm
150 mm
Detection range (H)
Setting distance (L)