User Manual
76
Section 4 SETTING OF INSPECTION CONDITION
ZFV-C
User’s Manual
Section 4
Inspecting by Position (POSITION)
■ Adjusting the threshold level
CUSTOM Menu
Items that can be customized
Setting item Range Details of Adjustment
Edge position 0 to 468 Amount of shift from reference position
Edge level 0 to 100 This is the density level judged to be an edge.
Adjust this level when measurement is unstable.
p.73
Items that can be customized Page
Items related to
edge detection
Selecting the color of edges p.77
Selecting the edge detection direction p.77
Changing edge sensitivity p.77
Items related to
color
Changing the color mode (default: [FILTER]) p.74
Changing the filter color (only when [FILTER] is selected in [COL MODE]) p.65
Teaching Brightness (only when [PICKUP] is selected in [COL MODE]) p.65
ADJ
RUNMENU
POSITION
OK
POSITION
OK
120
GAP [ 150]
EDGE LEV [ 50]
:LEV CHANGE
● Adjustment of edge
position
● Switching to
ADJ mode
Measured
values
● Adjustment of
edge level
Amount of shift
Threshold
Edge level
UP/DOWN keys: Change values.
Edge level
UP/DOWN keys: Change values.
• When edge detection direction is →
LEFT/RIGHT keys: Change values.
• When edge detection direction is ↓