User Manual
68
Section 4 SETTING OF INSPECTION CONDITION
ZFV-C
User’s Manual
Section 4
Inspecting by the Size (Area)
Basic Setting Procedure
■ Teaching
Teaching is performed after the object and color to be inspected are specified.
Application and Setting Examples p.152
■ Adjusting the threshold level
Threshold values are adjusted to determine the range for OK judgments.
Adjust the threshold values referring to the currently indicated measurement results.
Adjustment of the threshold values must be performed in ADJ mode.
● AREA1/AREA2/AREA3
Setting item Range Details of Adjustment
Area value 0 to 999 This is the range for OK when the value at teaching is taken to be 100 %.
If AREA2 is selected, the same judgment conditions will be used for all the four
colors. Judgment is made based on the color, among the four colors, that has the
largest difference from the reference value.
TEACH/PICK
SEL
AREA2
OK
1
point
1
point
ITEM
REG.
PICK.
:VOID
D: HIST
Color Selection
Inspection
area setting
Teaching
80
ADJ
RUNMENU
L: [ 80] H:[ 120] B
AREA1 OK
1
point
● Adjusting of area value
● Switching to ADJ
mode
LEFT/RIGHT keys: Select upper limit/
lower limit.
UP/DOWN keys: Change values.
Upper/lower limit
Measured values
Lower limit Upper limit