Section 2 INSTALLATION & CONNECTION
ZFV-C
User’s Manual
Section 2
Amplifier Unit
(6) TEACH (teaching input)
There are two teaching modes, workpiece stop teaching and workpiece move teach-
ing. These teaching modes can be selected in the menu.
Selecting the Teaching Mode from an External Device p.97
(7) TRIG (measurement trigger input)
There are two measurement modes, synchronous measurement and continuous
measurement. Which mode of measurement is to be performed in is selected in the
menu.
Selecting the Measurement Timing p.97
(8) BANK1 (bank switching input 1)
(9) BANK2 (bank switching input 2)
(10) BANK3 (bank switching input 3)
The bank No. can be switched when BANK1 to BANK3 are connected as follows.
Timing Charts p.42
Bank No. BANK1 BANK2 BANK3
BANK1 OFF OFF OFF
BANK2 ON OFF OFF
BANK3 OFF ON OFF
BANK4 ON ON OFF
BANK5 OFF OFF ON
BANK6 ON OFF ON
BANK7 OFF ON ON
BANK8 ON ON ON