User Manual

Section 7 APPLICATION AND SETTING
Section 7
Inspecting for the Presence of Electronic Components (Pattern)
151
ZFV-C
User’s Manual
Adjusting the Inspection Area
6. Select [REG.] and press the SET Key.
7. Adjust the size of the inspection area and
press the SET Key.
Enlarge/reduce the window’s green frame so
that the inspection area is slightly larger than
than the workpiece.
8. Adjust the position of the inspection area
and press the SET Key.
Move the green frame so that the target is cen-
tered in the inspection area.
Registering the Reference Workpiece
9. Press the TEACH/VIEW key.
“+” will begin to blink at the center of the
inspection area.
Teaching is completed when the “+” mark dis-
appears.
Checking Operation
10.
Switch the mode switch to “ADJ mode”.
11.
Check the measurement results displayed
on the LCD monitor.
TEACH/SEARCH
ITEM REG.
Zooms in/out
in vertical
direction.
Zooms in/out
horizontal
direction.
TEACH/REG.
SIZE
Vertical
direction
Horizontal
direction
TEACH/REG.
MOVE
TEACH/SEARCH
ITEM REG.
ADJ
RUNMENU
SEARCH
OK
99