User Manual

130
Section 6 APPENDIX
ZFV-C
User’s Manual
Section 6
Specifications and External Dimensions
Extension Cord
ZFV-XC_B(R)V2
* Model Nos. appended with R are robot cable types.
Item ZFV-XC3BV2 ZFV-XC3BRV2* ZFV-XC8BV2
Applicable Amplifier Units ZFV-C Series
Applicable Sensor Head ZFV-SC10/SC50/SC50W/SC90/SC90W/SC150/
SC150W
ZFV-SC10/SC50/SC50W
Ambient temperature Operating: 0 to +40 °C, Storage: -25 to +65 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35 % to 85 %(with no condensation)
Connection type Double-sided connector
Material Case: Polycarbonate (PC)
Weight Approx. 220 g Approx. 220 g Approx. 500 g
Cord length 3 m 3 m 8 m
Mounting
hole
Mounting hole dimensions
2-M3
Round PVC insulated cable
3375
13
8.5
45.9
L (Note 1)
28±0.1
28
2- 3.5
20 pins
20 pins
30
36
6.2, 20-wire
Note 1: L=3 m, 8 m (for ZFV-XC_BV2)
L=3 m (ZFV-XC_BRV2)
(Unit: mm)